Special Set-Up Procedure

Special Set-Up Procedure

WARNING – Turn off electrical power and disconnect power cord from

electrical supply before beginning special set-up procedure. If power cord is not disconnected, severe injury to personnel could result.

Changing Tape Leg Length

(From 70 to 48 mm [2-3/4 to 2 Inches])

The following changes to the case sealer will allow taping boxes 90 mm [3-1/2 inches] minimum height.

CASE SEALER FRAME (Refer to Figure 5-1A)

1.Raise the upper head assembly (by turning crank handle counterclockwise). Remove and retain the two screws and washers from the normal position holes "A-A".

2.Remount and secure the stop bracket in the lower position "A" using the top holes and original fasteners. Relocate both the right and left stop brackets.

TAPING HEADS

WARNING – Turn off electrical power and disconnect power cord from WARNINGS

1.Use care when working near tape cut-off knife as knife is extremely sharp. If care is not taken, severe injury to personnel could result.

2.Taping head weighs approximately 7.2 kg [16 lbs]. Use proper body mechanics when lifting upper or lower taping heads.

(Refer to Figures 5-1B and 5-1C)

1.Loosen, but do not remove, the two retaining screws that secure the upper taping head shown in Figure 5-1B.

2.Slide the head forward and lift straight up to remove it from the case sealer.

3.Lift the lower taping head, shown in

Figure 5-1C, straight up to remove it from the case sealer bed.

4.Refer to Section II (Taping Head), "Adjustments

– Changing Tape Leg Length", page 13 for taping head set-up.

Figure 5-1 – Removing Taping Heads From Case Sealer