3M 39600 manual 7 - Column Spacers/Columns

Models: 39600

1 70
Download 70 pages 16.15 Kb
Page 35
Image 35
Figure 5-7 – Column Spacers/Columns

Special Set-Up Procedure (Continued)

7.Remove fasteners (M8 x 16 socket head screws and M6 plain washers) that attach column spacers to machine bed and remove spacers/ outer columns from machine bed. Figure 5-7A.

8.Remove fasteners (M8 x 20 socket head screws) that attach spacers to columns, move spacer down 100 mm [4 inches] to lower set of mounting holes and re-attach spacers to columns. Figure 5-7B.

9.Reverse procedure, Steps 7-1 to reassemble machine.

Note When installing upper assembly back into machine (removed in Step 3), slide upper assembly down into outer columns until lead screws contact plastic nuts and support upper assembly. Then, slowly turn height adjustment crank counterclockwise until two "clicks" are heard, one at each plastic nut. Now the upper assembly can be cranked down (turn height adjustment crank clockwise) for installation of special nut on bottom of each lead screw.

Figure 5-7 – Column Spacers/Columns

30

Page 35
Image 35
3M 39600 manual 7 - Column Spacers/Columns