32
Special Set-Up Procedure (continued)
Moving the outer columns to the upper set of
mounting holes increases the maximum box size
(height) handled by the case sealer from 620mm
[24-1/2 inches] to 725mm [28-1/2 inches].
Note – this also increases the minimum box height
from 120mm [4-3/4 inches] to 210mm [8-1/4 inches].
13.11.4 Box Height Range
(Outer Column – Re-Positioning) To Re-position the outer columns:
1. Remove special nut from the bottom of each
column lead screw. Figure 13-11A.
2. Remove plastic column cap from the top of each
outer column as shown in Figure 13-11B.
3. Crank upper assembly up, out of plastic nuts.
Lift upper assembly up and out of outer columns.
Be careful not to damage lead screws - Figure
13-11C.
To reduce the risk associated with
mechanical and electrical hazards:
Turn electrical and air supply off and
disconnect before performing any
adjustments, maintenance, or servicing the
machine or taping heads
13-MAINTENANCE AND REPAIRS (continued)
2011 August
800a-NA
To reduce the risk associated with
muscle strain:
Use the appropriate rigging and
material handling equipment when
lifting or repositioning this equipment.
Use proper body mechanics when
removing or installing taping heads
that are moderately heavy or may be
considered awkward to lift.
WARNING
To reduce the risk associated with
mechanical and electrical hazards:
Allow only properly trained and
quali ed personnel to operate and service
this equipment.
WARNING