6. FUNCTION PARAMETER SETTINGS
To design a platform scale, set the capacity, weighing unit and other functions according to the specifications of the scale.
Normally, end users do not have to set these function parameters and these setting can be sealed together with the calibration switch.
Parameter
-C01-00
Function number
6-1. The procedure for setting parameters
Do not set
setting procedure again.
When turning the power on and the indicator may display
press the PRINT/ENT key to proceed to the weighing mode.
See “7. CALIBRATION” as for the location of the calibration (CAL) switch.
1. |
| In the weighing mode, press and hold the calibration (CAL) | |||||||||
|
| switch until |
| Cal |
|
| appears. Then, release the switch. | ||||
Press and hold the |
|
|
| key for about 5 seconds, then you | |||||||
| 0 | ||||||||||
|
| can also enter the calibration mode (when | |||||||||
Press the |
| ON/OFF |
| key or (CAL) switch to stop the | |||||||
| setting procedure. |
|
|
|
| ||||||
2. | Press and hold the |
|
| key and press the | |||||||
| ZERO | ||||||||||
|
|
| key. Then the first function number is | ||||||||
|
| PRINT/ENT | |||||||||
|
| displayed. |
|
|
|
|
|
|
|
|
3.Press the 2 key to enter into the “C02 Capacity” setting.
4.Press the PRINT/ENT key. Then the parameter stored appears.
5.Enter the parameter value for the capacity using the
6.Press the ZERO key to go to the next function number “C03 Weighing display unit”.
7.Set C03 “0” (metric unit), or “1”
8.The settings C02 and C03 are minimum requirements to design a platform scale. To finalize the settings, be
sure to press the PRINT/ENTER key. Then, the display shows end for a few seconds and returns to weighing mode.
-00Cal00
-C01-01 -C02-01 -C02-00 -C02-02 -C03-01 -00end00
The ZERO key increments the function number as in the step 6 above, but note that all of the new parameters are not stored until end is displayed.
To exit with nothing changed, turn the power off without pressing the PRINT/ENT key.
Set the other parameters according to the specifications required.
10