Cooling system fans

The Altos G900 server accommodates six hot-swap fan modules.

Caution! Don't remove a fan module while the server is powered on unless you have a replacement unit available. Once you remove a fan module from the system, replace it within five minutes. Vacant spaces alter airflow patterns in the server system and can cause overheating and damage to system components.

Checking a fan status indicator

Fault LED indicators for each fan module are located on the fan board. The indicators are visible through a cutout in the housing of each module.

Figure 46 - Fan status indicators

Label

Description

Label

Description

 

 

 

 

A

Fan board

B

Fan status LED indicators

 

 

 

 

The red LEDs light to indicate a fan failure; during normal operation, the LEDs remain unlit. A fan failure is also indicated by the general system fault LED located on the front panel.