4. Bright� | Blemish� |
|
Procedure |
| - Test equipment: video generator |
|
| - Test signal: analog 1024 x 768@60Hz |
|
| - Test Pattern: Gray 15 |
Inspection item | - Bright blemish check. | |
Criteria |
| - The bright blemish should be no more than 10 |
|
| under gray 15 pattern. |
|
| - Ref. Defect specification table. |
5. Dark Blemish� |
| |
Procedure |
| - Test equipment: video generator. |
|
| - Test signal: analog 1024x768@60Hz. |
|
| - Test Pattern: Blue 60 |
Inspection item | - Dark blemish check. | |
Criteria |
| - The dark blemish should be no more than 10 |
|
| under blue 60 pattern. |
|
| - Ref. Defect specification table |
6. Focus test
Procedure | - Test equipment: video generator. |
| - Test signal: analog 1024 x 768@60Hz |
| - Test Pattern: Full screen |
Inspection item | - Focus check |
Criteria | - From screen 2 M via visual to check the |
focus, look at the entire screen, focus shall
be clear, crisp, and sharp over the entire surface of the display pattern. (Blur word on one of the corner after adjustment is acceptable. However, the word should at least be recognizable.)
Gray 15
Blue 60
Full screen
P3150/P3250/P3150 Refresh/P3250 Refresh/P3251 | Confidential |
|
|
4-