2. Brightness
| Procedure | - Full white pattern | 
| 
 | - Use CL100 to measure brightness values of | 
| 
 | P1~P9. | 
| 
 | - Follow the brightness formula to calculate | 
| 
 | brightness values. | 
| 
 | ☼ Brightness Formula | 
| 
 | Avg.(P1~ P9)x1.1m2 | 
| Criteria | - 900 lumens | 
3. Ful On/Full Off Contrast
| Procedure | - Full white pattern & full black pattern | 
| 
 | - Use CL100 to measure brightness values of full | 
| 
 | white pattern P5 & full black pattern B5 ( see im- | 
| 
 | age: full white) | 
| 
 | - Follow Contrast formula to calculate contrast | 
| 
 | values. | 
| 
 | ☼ Contrast Formula | 
| 
 | P5/B5 | 
| 
 | Note: P5=center of white image | 
| 
 | B5=center of black image. | 
| Criteria | - 1400:1 | 
4. Uniformity
| Procedure | - Full white pattern | 
| 
 | - Use CL100 to measure brightness values of | 
| 
 | P1~P9 | 
| 
 | (see image: full white). | 
| 
 | - Follow the Uniformity formula to calculate | 
| 
 | average values. | 
| 
 | ☼ Uniformity Formula | 
| 
 | ANSI Uniformity = Avg. (P1, P3, P7, P9) | 
| 
 | /P5X100% | 
| Criteria | - 65% | 
Full white pattern
Full black pattern