P3150/P3250/P3150 Refresh/P3250 Refresh/P3251 Condential 4-1

Chapter 4

Function Test & Alignment Procedure

4-1 Test Equipment Needed

- IBM PC with SVGA/XGA resolution
- DVD player with Multi-system (NTSC/PAL/SECAM), equipped “Component”, “S-Video”
, “Composite” and "HDMI".
- HDTV Source (480P, 720P, 1080i)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- After changing parts, check the information below.

4-2 Service Mode

1. Turn on the projector and input the signal
2. Do the following actions sequentially to enter service mode menu
(1) Press "Power→Left→Left→Menu".
(2) Service mode will be shown.
(3) After conrming the conguration, press "Exit" to exit.

4-3 OSD Reset

1. After nal QC step, we have to erase all saved change again and restore the OSD
default setting. The following actions will allow you to erase all end-users' settings and
restore the default setting:
(1) Please enter OSD menu.
(2) To execute "Reset" function.