3-3 Main Procedure

No

Symptom

Procedure

 

 

• Ensure the Power Cord and AC Power Outlet are securely

 

 

connected

 

 

• Check Lamp Cover and Interrupt Switch

 

 

• Ensure all connectors are securely connected and aren’t

1

No Power

broken

 

 

 

 

• Check Lamp Driver

 

 

• Check LVPS

 

 

• Check Main Board

 

 

• Check LED Status

 

 

a. Power LED on(B/R), Lamp LED off, Temp LED on (R)

 

 

• Check Thermal Switch

 

 

• Check Fan

 

 

b. Power LED on(B/R), Lamp LED on (R), Temp LED off

 

 

• Check Lamp

2

Auto Shut Down

• Check Lamp Driver

• Check Main Board

 

 

 

 

c. Power LED on(B/R), Lamp LED off, Temp LED fl��ash (R)

 

 

• Check Fan

 

 

• Check Main Board

 

 

d. Power LED on(B/R), Lamp LED flash (R), Temp LED off

 

 

• Check Color Wheel

 

 

• Check Photo Sensor Board

P3150/P3250/P3150 Refresh/P3250 Refresh/P3251

Confidential

3-

Page 63
Image 63
Acer P3250 REFRESH, P3150 REFRESH service manual Main Procedure, Symptom