ARMC/3 module error beep codes

In addition to the beep codes above, additional beep codes are provided if an ARMC/3 module is installed. The management modules provide the following additional beep codes.

Beep

Reason for the beeps and action to take

Code

 

 

 

1

Control panel CMOS clear has been initiated.

 

 

1-5-1-1

Processor failure. Reseat or replace the failed processor.

 

 

1-5-2-1

No processor is installed or the CPU 1 socket is empty. Reseat

 

or replace the failed processor.

 

 

1-5-2-3

Processor configuration error or CPU 1 socket is empty. Reseat

 

or replace the failed processor. In a two-processor system,

 

make sure the processors are identical.

 

 

1-5-2-4

Front side bus selects configuration error

 

 

1-5-4-2

AC power unexpectedly lost

 

 

1-5-4-3

Chipset control failure

 

 

1-5-4-4

Power control failure

 

 