77
ARMC/3 (optional) or BMC module
The ARMC/3 or BMC module provides server management firmware and functionality for the system.
Removing the ARMC/3 or BMC module
1Observe the ESD precautions and
2Remove the memory boards or memory air baffles from DIMM slots C and D. See “Cold Removal of Memory Board” on page 70 and “Removing a memory board air baffle” on page 42.
3Hold the module both by the loop finger grip and by the opposite corner (A).
Caution: Do not bend or twist the module.
4 Pull up the module to remove it from the connector (B).
5 Observe the
Installing the ARMC/3 or BMC module
1Observe the ESD precautions and
2Remove the memory boards or memory air baffles from DIMM slots C and D. See “Cold Removal of Memory Board” on page 70 and “Removing a memory board air baffle” on page 42.