700-701-100-02Overview

 

Table 3. Line and Desktop Unit Front Panel Components

 

 

Name

Function

 

 

HDSL SYNC LED

Displays synchronization state for the HDSL loop.

HDSL ALM LED

Displays alarm state for the HDSL loop.

 

 

I/F ALM LED

Displays alarm state for the G.703 data port.

 

 

LOC LPBK LED

Displays local (LOC) loopback state.

LOC LPBK Button

Activates the local HDSL analog loopback.

 

 

REM LPBK LED

Displays remote (REM) loopback state.

REM LPBK Button

Activates the remote interface loopback.

 

 

V.24 (RS-232) console

Provides bi-directional communication between the unit and an external maintenance terminal through

port

a V.24 (RS-232C) interface to allow configuration and performance monitoring through the console

 

screen menus as described in “System Configuration” on page 25. This connector can also be used to

 

download new firmware to the line unit’s flash memory as described in “Firmware Download Utility” on

 

page 62. This port is configured as DCE (see “Maintenance Terminal Connection” on page 25 for

 

pinouts).

 

 

Bar code label (all units)

Contains the serial number and part number of the unit, as indicated in both bar code and text format.

 

Also contains the configuration number of the unit, as indicated by "CFG: Rnn," where nn is the

 

configuration number. For example, CFG: R07 would indicate configuration number 07.

 

 

Warranty control

Indicates the beginning year and month of the line card warranty. Also indicates the line card revision

number label (UTU-701C)

number. For example, a warranty control number of "803R07" would indicate a warranty beginning in

 

the year 1998 (8), during the month of March (03), and line card revision number R07.

 

 

Unit ID label (ETU-751C)

Identifies the model number, manufacturer, part number, and input voltage range of the ETU. Includes

 

the CE mark, certifying that the unit is in compliance with directive EN300 386-2. See “Certification and

 

Warranty” on the inside of the back cover.

 

 

UTU-701 and ETU-751 List 1

August 9, 2002

5