700-701-100-02

Viewing Status

 

 

HDSL Span 1 Alarm History Screens

At the History HDSL Span 1 menu (Figure 38), type A to select the Alarm History status screen for HDSL Span 1 (Figure 41).

Figure 41. Alarm History Status Screen for HDSL Span 1

Table 28 describes the four columns of data contained in each HDSL Span Alarm History screen.

 

Table 28. HDSL Span Alarm History Data

 

 

Column

Description

 

 

Alarm

Type of alarm: MAR1 (Margin Span 1), ES1 (Errored Seconds Span 1), LOSW1 (Loss

 

of Sync Word Span 1), PFO1 (a) (Power Feed Open Span 1), PFS1 (a) (Power Feed Short

 

Span 1)

First

Date and time the alarm first occurred

Last

Date and time the alarm last occurred

Count

Number of times the alarm has occurred since the alarms were last cleared

(a) Not supported. These units do not supply power to other units.

If no alarm has occurred since the last alarms were cleared, the message "No alarms reported" displays on the appropriate line for each alarm.

UTU-701 and ETU-751 List 1

August 9, 2002

57