Specifications | |
|
|
Can be individually set to Disabled, Minor, or Major (major alarms actuate the LTU or NTU alarm relay)
E1 Interface | Loss of Signal (LOS) |
| Loss of Framing (LFA) |
| Alarm Indication Signal (AIS) |
| Remote Alarm Indication (RAI) |
External Clock | Loss of Clock (LOC) |
HDSL Loop | Margin, programmable threshold (MAR) |
| Errored Seconds, programmable threshold (ES) |
| Loss of Sync Word (LOSW) |
History |
|
E1 and HDSL Interface | |
| ES and UAS |
Alarm | Time stamp of first and last occurrence, number of occurrences for |
| all enabled alarms |
Power Requirements |
|
| |
Local input voltage | |
Consumption (typical) | 4.5 W |
| |
Local input voltage | 100 to 240 volt, 50 or 60 Hz, AC power |
Consumption (typical) | 4.5 W |
Environmental |
|
Operating Temperature Range | 0 ° C to +50 ° C (32 °F to 122 °F) |
Humidity | Up to 95% |
Storage Temperature | |
Storage Humidity | 5% to 95% |
Regulatory Approvals |
|
CE Mark Certification | EN300 |
10 | August 9, 2002 |