System Configuration

700-701-100-02

 

 

Table 21. Fields Displayed in Config Alarms HDSL Span 1 Menu

 

 

Field

Description

 

 

Margin (MAR)

Selects whether the alarm is disabled (DIS), or enabled and reported as a Minor (MIN) or Major

 

(MAJ) Alarm when the margin falls below the threshold. This indicates a potential degradation of

 

line quality. If an alarm is configured as a protection switch (PSW), it will behave as a Major (MAJ)

 

Alarm, and cause protection switching to engage.

Margin Threshold

Selects the margin alarm threshold (from 0 dB to 15 dB) for all four margin measurements of the

 

span.

Errored Seconds (ES)

Selects whether the alarm is disabled (DIS), or enabled and reported as a Minor (MIN) or Major

 

(MAJ) Alarm when 24-hour ES count exceeds the threshold.

24 HR ES Threshold

Selects the errored seconds threshold (0 to 255) for all four errored seconds measurements of the

 

span measured over a 24-hour period.

Loss of Sync Word (LOSW)

Selects whether the alarm is disabled (DIS), or enabled and reported as a Minor (MIN) or Major

 

(MAJ) Alarm when the LOSW condition (HDSL loop down) occurs.

Power Feed Open

Not supported. These units do not supply power to other units.

Power Feed Short

Not supported. These units do not supply power to other units.

 

 

SET TO FACTORY DEFAULTS

Set to Factory Dflts is the screen from which all operating options can be reset to the ADC factory defaults.

1Type F at the Config drop-down menu to display the Set to Factory Dflts screen (Figure 28).

Figure 28. Set to Factory Defaults Screen

2Press ENTER to reset value to factory defaults. A confirmation message appears at the bottom of the display:

SETTING FACTORY DEFAULTS ... SERVICE *WILL* BE INTERRUPTED! ARE YOU SURE(Y/N)?

44

August 9, 2002

UTU-701 and ETU-751 List 1