Table 20. Fields Displayed in Config Alarms LTU and Config Alarms NTU Interface Menus
Field | Description |
|
|
Loss of Signal (LOS) | Loss of signal at the G.703 input. |
Loss of Frame Alignment (LFA) | Loss of frame alignment at the G.703 input. |
Receive Alarm Indication Signal (AIS) | Alarm indication signal (unframed all ones) received at the G.703 input. |
Remote Alarm Indication Signal (RAI) | Remote alarm indication signal received at the G.703 input (through |
Loss of Clock (LOC) | Applies to loss of external clock when EXT timing is used. The external clock was lost for |
| the previous second. This alarm is reset when the clock is active again. |
|
|
HDSL Span 1 Alarms
1Type 1 at the Config Alarms
Figure 27. Config Alarms HDSL Span 1 Menu
2Do the following for each interface option to be changed. The fields displayed in the Config Alarms HDSL Span 1 menu are described in Table 21 on page 44.
• Use the ↑ or ↓ key to select the
•Use the SPACEBAR to toggle to the appropriate option or type in the correct information, then press ENTER to select the option.
August 9, 2002 | 43 |