700-701-100-02

System Configuration

 

 

Configure LTU and NTU Interfaces

Select and configure the LTU- and NTU-related operating parameters as follows:

1Type one of the following at the Config drop-down menu to display the Config LTU or NTU Interface menu:

L for the Config LTU Interface menu (Figure 22).

N for the Config NTU Interface menu (Figure 23).

Figure 22. Config LTU Interface Menu

Figure 23. Config NTU Interface Menu

The Data Rate/# of TSs and Beginning TS parameters in the Config LTU and NTU Interface menus are read-only displays. The Data Rate/# of TSs value is set in the Config System Settings menu as the “HDSL Payload Rate” (See Figure 21 on page 37). The Beginning TS value is 0 with 32 time slots selected (unstructured mode) and 1 when less than 32 time slots are selected (structured mode).

UTU-701 and ETU-751 List 1

August 9, 2002

39