700-701-100-02

Functional Description

 

 

Power Sources

The line and desktop units receive power from the following sources:

A shelf-mounted UTU-701C receives power from a local source of -36 Vdc to -72 Vdc.

An enclosure mounted UTU-701C receives power from a local source of -36 Vdc to -72 Vdc or from the enclosure’s built-in AC-to-DC power supply (when provided).

The ETU-751C desktop unit receives power from a source of 100 to 240 volt, 50 or 60 Hz, AC power.

Input voltage for the UTU-701C line unit (nominal -48 Vdc, tolerance -36 to -72 Vdc) must be supplied by an isolated DC source that complies with TNV or earthed SELV requirements of the latest version of IEC 950.

The single-pair rate selectable HDSL units (local and remote) must be locally powered.

UTU-701 and ETU-751 List 1

August 9, 2002

13