Unit Installation

NetVanta 4300/4400 Series

 

 

 

 

 

Instructions for Rack Mounting the NetVanta

 

 

Step

Action

1Position the NetVanta in a stationary equipment rack. This unit occupies 1U of space. To allow proper grounding, scrape the paint from the rack around the mounting holes where the NetVanta will be positioned.

2Have an assistant hold the unit in position as you install two mounting bolts through the unit’s brackets and into the equipment rack using a #2 Phillips-head screwdriver.

3Proceed to the steps given in Supplying Power to the Unit on page 49.

Wall Mounting NetVanta 4300/4400 Series

By following these instructions exactly, the NetVanta can be safely mounted to the wall.

To avoid damaging the unit, use only the screws included in the shipment when attaching mounting ears to the chassis.

When wall mounting the NetVanta, care must be taken not to damage the power cord. Do not attach the power cord to the building surface or run it through walls, ceilings,

floors, or openings in the building structure.

The socket-outlet must be installed near the equipment and must be easily accessible.

When wall mounting the NetVanta 4430, do not remove the SFP slot covers unless an SFP has been installed in the slot.

 

Instructions for Wall Mounting the NetVanta

 

 

Step

Action

 

 

1

Remove the mounting ears from the NetVanta. Rotate them 90o so that the portion of the

 

bracket with the mounting holes is flush with the bottom of the chassis. Reattach them to the

 

chassis (see Figure 20 on page 49).

 

 

2

Decide on a location. All NetVanta 4000 Series units are mounted with the front panel facing

 

up. Keep in mind that the unit needs to be mounted at or below eye level so that the LEDs are

 

visible.

 

Important! Mount the chassis with LEDs facing up (not facing sideways or down).

 

Important! When wall mounting the NetVanta 4430, do not remove the SFP slot covers unless

 

an SFP has been installed in the slot.

 

 

3

Prepare the mounting surface by attaching a board (typically plywood, 3/4-inch to 1-inch thick)

 

to a wall stud using #6 to #10 (2.5-inch or greater in length) wood screws.

 

Important! Mounting to a stud ensures stability. Using sheetrock anchors may not provide

 

sufficient long-term stability.

 

 

4

Have an assistant hold the unit in position as you install two #6 to #10 wood screws through the

 

unit’s brackets and into the mounted board.

 

 

5

Proceed to the steps given in Supplying Power to the Unit on page 49.

 

 