ADTRAN 4200659L3 Trap, If enabled, the unit issues a trap when, Los/Ais, Disabled, Normal, Fail

Models: 1200287L1 1200291L1 1200657L2 4200659L4 4200659L6 4200659L3 4200659L7 4200659L2 4200659L8 4200659L5 4175043L2 4200659L1

1 192
Download 192 pages 19.94 Kb
Page 78
Image 78
Trap

Chapter 3. Configuration

Trap

If enabled, the unit issues a trap when...

 

 

System Timing

 

 

 

Clock Status

there is a change in clock status. The clock

 

status can be any of the following values:

 

NORMAL – clock synchronization is

 

operating normally.

 

RECOVERING – clock synchronization is in

 

the process of recovering from a fault.

 

LOSS OF SOURCE – the reference clock

 

source has become invalid

 

OUT OF RANGE – the clock synchronization

 

circuit is unable to track the reference

 

source.

 

OUT OF LOCK – the clock synchronization

 

circuit is unable to lock to the reference

 

source.

 

 

Clock Source

there is a Clock Source Change event

Change

indicating that the unit has switched clock

 

sources. The values for the clock source

 

change alarm are:

 

Loop

 

PRI Ext

 

SEC Ext

 

Free-run

 

Holdover

 

 

PRI EXT Clock

a failure condition is encountered on either the

Status

PRImary or SECondary clock sources (if

 

configured). The possible values for this alarm

 

are:

 

DISABLED

 

NORMAL

 

AVAILABLE

 

LOS/AIS

 

FAIL

 

UNAVAILABLE

 

 

3-32

MX2800 STS-1 User Manual

61200659L1-1