ADTRAN 4200659L3 Circuit And Network Failure Recovery Mode, Selection Path, Recommended Setting

Models: 1200287L1 1200291L1 1200657L2 4200659L4 4200659L6 4200659L3 4200659L7 4200659L2 4200659L8 4200659L5 4175043L2 4200659L1

1 192
Download 192 pages 19.94 Kb
Page 138
Image 138
Table 7-1. Configuration Requirements for Circuit Recovery

Chapter 7. Circuit and Network Redundancy

Table 7-1. Configuration Requirements for Circuit Recovery

Selection Path

Recommended Setting

 

 

Config > Network Interface > XCV Threshold

1E-3 (see the following note)

 

 

Config > Network Interface > Network Protection

Disabled

 

 

Config > Network Interface > Max. Switch Threshold

3

 

 

Config > Network Interface > Min. Switching Period

10 seconds

 

 

Config > T1/E1 Interface > T1/E1 Circuit Protection

Enable all or select the

 

T1/E1s that redundant

 

switching should occur on.

 

 

Config > T1/E1 Interface > XCV Threshold

1E-3 (see the following note)

 

 

The XCV Threshold settings are based on the error rates considered acceptable on the STS-1 or DS-1 before switching.

CIRCUIT AND NETWORK FAILURE RECOVERY MODE

In this mode, two controller cards are installed and connected to two individual STS-1 lines. This is, of course, the most complete mode of redundancy. In this mode, the primary controller card is connected to the primary STS-1 line and the secondary controller card is connected to the secondary STS-1 line. The primary card and line actively transmit data, while the other card and line stand by ready to take over if the first card and line fail. For example, if CARD A fails, then control switches to CARD B and NET B.

An important feature of the MX2800 STS-1 is its ability to internally re-route the network connection if a controller card and the opposite network connection fail. For example, in the illustration given in Figure 7-3, failed NET A is connected to healthy CARD A; and healthy NET B is connected to failed CARD B.

7-4

MX2800 STS-1 User Manual

61200659L1-1

Page 138
Image 138
ADTRAN 4200659L3, 4200659L1 Circuit And Network Failure Recovery Mode, 1. Configuration Requirements for Circuit Recovery