Total Access 600 Series SHDSL IAD User Interface Guide/64200683L1-31B

Page 46

Sys log Host

Set this to the IP address or domain name (if DNS configured) of the sys log host device. All log events are sent to this device.

PPP Log

Information pertaining to the PPP negotiation and authentication is logged in the PPP log.

Connection Log

Information pertaining to the call placement and answering is logged in the Connection log.

Network Log

Information pertaining to routing protocols is placed in this log.

Each log (PPP log, Connection log, and Network log) contains the following elements.

Active

When set to ;￿￿ (def), PPP events below or equal the log level are logged into the log.

Wrap

When set to ;￿￿ (def), new PPP events will overwrite old PPP events when the log is full. All logging will stop when the log is full and set to ￿￿.

Level

In order to log events, they must be at or below this level. Range is 0 to 6. The default is 3.

View

This menu displays the log list. The fields are as follows:

DATE/TIME

LEVEL

MESSAGE

Clear

Date and time event occurred.

Level associated with this event (0-6).

Text message for this event. If message is too long to fit on the line, another event appears below it continuing the message.

This clears the log when activated.

Total Access 600 Series User Manual

© 2002, ADTRAN, Inc.

Page 46
Image 46