NetVanta 1000/1000R Series Hardware Installation Guide

Option Modules

 

 

NetVanta SHDSL NIM, Annex B (P/N 1200937E1)

The NetVanta SHDSL NIM, Annex B (shown in Figure 32) provides a WAN SHDSL interface for the NetVanta. See Table A-10on page 70 for the SHDSL connector pinouts.

WAN-SHDSL

ANNEX B

Figure 32. NetVanta SHDSL NIM, Annex B

Features and Specifications

Operating Mode

Line termination (CO)

Network termination (CPE)

SHDSL Interface

Supported Standards: ITU-T G.991.2 SHDSL, Annex B

M-pair bonding of 2 pairs - ITU.T G.991.2

Line Rate (2-wire mode): 192 to 2304 kbps in 64k increments

Line Rate (4-wire mode): 384 to 4608 kbps in 128k increments

Payload: ATM (AAL5)

Line Code: TC-PAM

Connector: RJ-45

Clock Source

CPE Operating Mode: Network

CO Operating Mode: Internal

Diagnostics

Network loopbacks (local and remote)

Alarm generation and detection

Programmable alarm threshold setting for loop attenuation and signal-to-noise ratio

Compliance

EMC - see Electromagnetic Compatibility (EMC) Table on page 6.

AS/ACIF S043

EN 60950

AS/NZS 60950

RoHS compliant (Telecommunications exemption)

Environmental

Operating Temperature: 0°C to 50°C

Storage Temperature: -20°C to 70°C

Relative Humidity: Up to 95 percent, noncondensing

Physical

Dimensions: 2.75-inch W x 4.25-inch D

61200500L1-34N

Copyright © 2008 ADTRAN, Inc.