1.5.3 Function key <F2>

To switch the eye mark " of a computer on or off. First, use the <UP> and <DOWN> arrow keys to highlight it, then press <F2> to switch its eye mark on or off. If Scan Type is 'Ready PC +"', only the power-on and eye mark selected computers will be displayed sequentially in Scan mode.

1.5.4 Function key <F3>

To lock a device (a computer or a Slave) from unauthorized access, use Security. Security is effective for only one device (a computer or a Slave). To lock a device, use the <UP> and <DOWN> arrow keys to highlight it, then press <F3>. Now, enter up to 4 characters ('A'~'Z', '0'~'9, '-') followed by <ENTER> as new password. A Security-enabled device is marked with a “lock symbol” following its channel number. To permanently disable the security function from a locked device, highlight it, press <F3> then enter the password.

If you want to access the locked device temporarily, simply highlight it and press <ENTER>, the OSD will ask you for the password. After entering correct password, you are allowed to use the device. This device is automatically re-locked once you switch to another one. During Scan mode, OSD skips the security-enabled device.

Note: Only one device (a computer or a Slave) can be locked by this function at a time.

Note!: If you forget the password, the only way to permanently disable the security function is to remove all possible power sources from the RMD-1150F-8. You will need to turn off all computers and unplug the RMD switch power adapters, then restart everything.

RMD-1150 Series User's Manual

1 8

Page 18
Image 18
Advantech RMD-1150 user manual Function key F2, Function key F3