ARE I2 / RS 232 – Installation Guide
6 Settings of the Reader / Most Important Parameters
The default value of the operating mode parameter is 2..
•MD 2 triggered by an software command – default value
•MD 0 continuos mode
6.1General
The command set described below defines the transfer of data on the serial interface.
The commands consist of a command code and optionally of a parameter value. Commands are terminated by the control character <CR> (13h). The control character serves as com- mand line terminator.
Command codes and parameters, that means all letters and numerical values, are princi- pally transmitted as a sequence of ASCII characters (the value 255 (decimal) consequently as 32H, 35H, 35H; the command RST as 52H, 53H, 54H).
The protocol format is as follows
command <SP> parameter <CR>
The space character <SP> separates commands from parameters and the <CR> character acts as command line terminator.
For commands without parameter values (e.g. GT ) the <SP> character and parameter val- ues are omitted. The command line is as short as this:
command <CR>.
Generally, every input terminated by <CR> is acknowledged by the reader. The following response protocols are different:
Generally, every input terminated by <CR> is acknowledged by the reader. The following response protocols are different: