Manual

Page 18 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

0

1

one out of one (no effect)

two out of two ; (default value)

Output (example):

1 <CR>

 

 

 

 

 

Sequence of readings

 

Length of the reading cycle

Result of the reading cycle

NoRead

 

1 reading

NoRead

0000125ED1, 0000125ED1

 

2 readings

0000125ED1

0000125ED1, 0000126ED1

 

2 readings

NoRead

Schedule 6-: example for a reading cycle with NID=1

Example: A, B, C are specific different transponder numbers, N is NoRead:

Sequence of reading cycles

Output sequence after

Output sequence after

 

filtering with CN=0 and

filtering with CN=1 and

 

CID=1

CID=1

N, N, ......,N, A, A, A, ....A, N,N,

N, N, ......,N, A, N, N,

A

 

.......

 

N. N, N, A, A, A, N, A, A, B, A, C, C, C,

N. N, N, A, N, B, A, C,

A, B, A, C

 

.....

 

N, N, B, B, B, B, B, N, N, N, B, B, B, B, N,

N, N, B, N, N, N, N, N,...

B

N,...

 

 

N, N, N, B, B, B, B, B, N, B, B, B, B, N, N, N,

N, N, N, B, N, N, N, N,

B

....

....

 

Table 6-: example for the effect of the CID function

Annotation:

The internal reference number is deleted in the following conditions:

 

after a cold start

 

after a warm start

 

after entering the command line CID <SP> 1 <CR>

 

This causes that the next transponder code is output definitely.

Caution:

The filter function CID picks up the results of the complete reading

 

cycles, while the parameter NID proceeds from the results of single

 

readings! The filter function CID has effect on the serial interface

 

only.