Manual

Page 19 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

6.6EC- Echo

The command EC changes of the echo function setting.

Input format:

EC <SP> parameter <CR>

Parameter:

 

 

 

 

 

 

 

 

 

 

 

 

v

 

Function

 

 

 

0

 

echo on

 

 

 

1

 

echo off

 

Output (example):

0 <CR>

 

 

Note:

The default value of the parameter EC depends on the particular

 

 

reader.

 

 

6.7BD- Baudrate

The command BD enables the change of the baud rate. The settings are effective after a warm start using the RST command.

Input format:

BD <SP> parameter <CR>

Parameter:

 

 

 

 

 

 

Parame-

Function

 

ter

 

 

 

 

 

0

4800 baud

 

1

9600 baud

 

2

19200 baud

Output (example): 2 <CR>

AEG

Identifikationssysteme GmbH

Söflinger Straße 100 D-89077 Ulm

Tel. ++49(0)731-933-1340/1877 Fax ++49(0)731-933-1855e-mail: info@AEGID.de

Page 19
Image 19
AEG ARE I2 manual EC- Echo, BD- Baudrate