ARE I2 / RS 232 – Installation Guide

Inside of the SAB Cap there are the pins of following connections:

power supply

data link to the serial interface RS232

The codes to order the SAB Cabs and preassembled cables are listed below:

ID 70212

SAB-Cab incl. one PG9 cable pipe and 5 wire cable (standard cable)

ID 70213

SAB-Cab incl. one PG9 cable pipe and 5 wire cable / Sub D 9 Connector

 

(Service Cable)

ID 70221

SAB-Cab incl. one PG9 cable pipe

ID 70215

SAB-Cab incl. two PG9 cable pipes

ID 70219

SAB Cab without any cable pipe. The cabling is done by the customer himself.

4.3.1 Allowed Diameter of the Used Cables

The allowed diameters of the cables used for data link and power supply must be in the range from 3,5 to 8mm. For this case, IP 65 is reached.

4.3.2 Assembling of the Cable Pipe

If no preassembled SAB Cab are used (Best-Nr. ID 70214), the assembling must be done in following way:

Breakthrough the prepared areas at the surface of the SAB Cabs. There are two prepared areas seen at the SAB Cab: central and at one side of the cab.

The sealing must be done in the correct way O-Ring (3) at the cable pipe (4) (see also Figure 4-1.

2

4

 

 

3

1

Figure 4-1:Assembling oft the Cable Pipe

Bring the nut (2) of the cable pipe inside of the SAB Cab (1).

To fasten the nut please use the right tool (17mm)..