Figure 7.1.2 : Software triggered reading operation with TOR>0
Please note: The TOR parameter is only active, if the GT-Command is applied. Within the
time span defined by the value of TOR no NoRead will be output on the interface!
7.1.1 Settings of the Reader / Most Used Parameters
The default operation mode is changed by sending a software command to the reader.
In combination with an R / W transponder, the serial number of the transponder device is read
out only.
MD 2 - triggerd by an software command
most used parameters.
CID 0 - no suppression of repeatedly read Ids
CN 0 - no suppression of NoReads
NID 1 failure protection.; selection guide 2 out 2 transponder codes
TOR XYZ maximum reading time after the standard read command
is applied to the reader. The chosen value must match the
timing demands of the production process.
TOR 5 Default value
exciter
processor
interface
TOR
GT
reading process
NoRead
reading cycle reading cycle reading cycle