Troubleshooting - 3
J307 Voltage Measurements
Cable W9 connects J307 of the A1 Main Board Assembly to J207 of the A2 Interface Assembly. Table
Table 3-4. Voltage Measurements at J207 (A2 Interface to A1 Main board)
A1J207 | Signal Name | CV Mode | CC Mode |
Pin # |
| Full Scale Voltage | Full Scale Voltage |
|
| No Load | Full Load |
1 | PM_INHIBIT (Enabled) | 0 | 0 |
2 | OV_SCR* | +5 | +5 |
3 | OV_PROG | +3.9 | +3.9 |
4 | FAN_PROG | +2.8 | +3.8 |
5 | OV_DETECT* | +5 | +5 |
6 | SW_POS (Norm) | +5 | +5 |
7 | RANGE_SELECT (High) | 0 | 0 |
8 | OS_TRIM_NEG (COMP) | +1.7 | +1.7 |
| OS_TRIM_NEG (SCPI) | +4.0 | +4.0 |
9 | +5Vs | +5 | +5 |
10 | COMMON | 0 | 0 |
11 | COMMON | 0 | 0 |
12 | +15Vs | +15 | +15 |
13 | |||
14 | HS_THERM (@25C) | +2.5 | +2.5 |
15 | FUSE | +2.4 | +2.6 |
16 | IMON_H | 0 | +3.5 |
17 | IMON_L | 0 | +14.7 |
| IMON_L (@20mA Out) | +4.8 | +4.8 |
18 | IMON_P | 0 | 0 |
19 | VMON | +4.8 | +4.8 |
20 | COMMON | 0 | 0 |
21 | COMMON | 0 | 0 |
22 | COMMON | 0 | 0 |
23 | COMMON | 0 | 0 |
24 | CV_PROG | ||
25 | CC_PROG | ||
26 | CC_DETECT* | +5 | 0 |
27 | CCN_DETECT* | +5 | +5 |
28 | CV_DETECT* | 0 | +5 |
35