VMUX? < ch > , < x >
VOUT? < ch >
VRDAT < ch >, < Vlo >,
<Vhi > VRLO < ch > VRHI < ch > VRSET < ch > ,x
VRSET < ch > VSET < ch >, < x > VSET? < ch >
VSTEP< ch > , < x >
Table C-2 Command Summary (continued)
Queries the measurement of the input < x > to the analog multiplexer on the specified output < ch > (see Appendix A).
Queries the measured output voltage of the specified output < ch > (see page 70). The response is a real number. The front panel display can be used to monitor the measured output voltage (and current) of the selected output channel.
Used to calibrate the voltage readback for the specified output < ch > . This command must be sent after VRHI and VRLO commands.
Finds the minimum voltage readback value for the specified output < ch > .
Finds the maximum voltage readback value for the specified output < ch >.
Sets the full scale voltage range for prograrnming an output < ch > . The power supply will select the lowest operating range that will contain the value (x). If the present operating voltage of the supply is greater than the full scale range selected, the present output voltage will be reduced to the full scale value of the new range. If the voltage entered is larger than the highest possible range, an error message will result.
Queries the full scale voltage range setting of an output < ch >.
Sets the voltage of the specified output < ch > (see pages
Queries the present voltage setting of the specified output < ch > (see page 72). The response is a real number.
Increases or decreases an output’s < ch > voltage in steps. If the step value < x > is positive, the output voltage will increase by step value; if the step value is negative, the output voltage will decrease by the step value. Trying to step beyond the active operating range will cause a number range error.