6628A, 6626A, 6625A, 6629A manual
Models:
6629A
6625A
6626A
6628A
1
69
123
123
Download
123 pages
32.12 Kb
66
67
68
69
70
71
72
73
<
>
Specification
Supplemental Characteristics
Install
Error messages
Dimension
Connecting The Load
If not 6626A 2A use setup
Sending a Remote Command
Alignment Procedures
Error Detection
Page 69
Image 69
Figure
5-2
(Sheet 2 of 2). Syntax Forms For Power Supply Commands
Remote Operation
69
Page 68
Page 70
Page 69
Image 69
Page 68
Page 70
Contents
Microfiche Part No September
Agilent Part No
Certification
Safety Summary
Environmental Conditions
Safety Summary
USA
Declaration of Conformity
What this Manual Contains
Table Of Contents
Local Operation
Remote Operation
Command Summary
Alignment Procedures
Error Messages
Programming With a Series 200/300 Computer
Page
General Information
Safety Considerations
Introduction
Instrument and Manual Identification
Description
Accessories
Model
Output Combinations Available
General Information
GP-IB Board
Basic Operation
Output Boards
Specifications
Qualifying Conditions
Definitions
Specifications
Output Power Watt Output
Load Effect Regulation
Load Transient Recovery Time all outputs
Specifications Source Effect
Supplemental Characteristics
Temperature Coefficient-Programming
Temperature Coefficient-Measurement
Supplemental Characteristics Output Power Watt Output
AC Input Power
Programming Resolution
Command Processing Time see Figure
Supplemental Characteristics High Line Inrush Current Opt
Safety Agency Compliance
Dimensions all models
Load Cross Regulation
Supplemental Characteristics Weight
Page
Output Noise Typical CC Mode
Page
Page
Installation
Initial Inspection
Location and Cooling
Line Fuse
Input Power Requirements
Nominal Voltage
Line Voltage Range
Line Fuses
Fuse Agilent Part Number for ¼ X 1¼ in. fuses
Only
Line Voltage Conversion
Power Cord
GP-IB Interface Connector
Page
Getting Started
Front Panel Controls and Indicators
GP-IB
45.153 14.235m
Controls and Indicators Controls/Indicators Description
Output Control Keys These twelve keys are output dependent
Line switch
Normal Self Test Indications
Turning On Your Supply
Typical Display at Power-On Self-Test Errors
Checking Out Your Supply Using Local Control
Voltage Test
Overvoltage Test
Current Test
Introduction To Remote Operation
Changing Resolution Range
OCP
Range V/I
Output
Enter/Output Statements
Reading the GP-IB Address
Addr
Often Used Commands
Sending a Remote Command
Getting Data From The Supply
Disp a
Getting Started
Returning the Supply to Local Mode
Page
Output Ranges
Output Connections and Operating Information
Operating Quadrants
Output Connections and Operating Information
Protection Features
Wire Size Selection
Connecting The Load
Cross Section
Feet
Meters
Multiple Loads
Positive and Negative Voltages
Remote Voltage Sensing
Remote Sense Connections
Remote Voltage Sensing
Programming Response Time with an Output Capacitor
Overvoltage Trigger Connections
Open Sense Leads
External Trigger Circuit
Battery Charging
Power Supply Protection Considerations
Parallel Operation
Output Type
11. Parallel Connections with Local Sensing CV Operation
Remote Sensing
CC Operation
13. Series Connections with Local Sensing CV Operation
Series Operation
CC Operation
Bi-Polar Operation
Page
Remote Operation
GP-IB Operation
Interface Functions
GP-IB Address Selection
Power-On Service Request PON
Programming Syntax
Syntax Remote Operation
Output Channel
Output Channel Data Range
Syntax
Numeric Data
Page
Page
Header Note
Power Supply Queries Query
Response
Initial Value
Initial Conditions
Power Supply Commands
Initial Conditions
Parameter Inital Value
Output Outputs
Avg. Res 6625A / 6628A 6626A / 6629A
Range Programming
Current Programming
Output On/Off
Overvoltage OV Protection
Ovrst
Overcurrent Protection OCP
Multiple Output Storage & Recall
STO
Status Reporting
Clear Command
UNR =
UNR +CC
Unmask 2,XXX
Bit assignment of the Serial Poll Register
RQS ERR RDY FAU
SRQ?
Service Request Generation
Conditions for Generating a Service Request
Commands Sent
State RQS Bit Reprogramming Delay
Display On/Off
DSP Output 2 OK’’
Output 705 Dspoutput 2 OK
ERR?
Other Queries
Explanation Response Code
Front Panel
Front Panel Response
Error Messages GP-IB Explanation Code
Test Responses
Code Explanation
Local Operation
Local Mode
Local Control Of Output Functions
General
Front Panel Model 6626A shown
Setting Voltage and Voltage Range
Enabling/Disabling an Output
Setting Current and Current Range
Local Control Of System Functions
Displaying Error Messages
STO Enter
RCL Enter
Page
Alignment Procedures
Test Equipment and Setup Required
Calibration Program
Alignment Procedures
Figure A-1
Figure A-3
Printer is
Alignment Program
Subend
Else
END if
Print
Pause
Wait
Repeat
2270 Print The current shunt is used 2280
If not 6626A 2A use setup
Wait for source to stabilize
END if Subend
Stop
Programming With a Series 200/300 Computer
Path Names
Voltage and Current Programming
Voltage and Current Readback
Voltage and Current Programming with Variables
Print Output 1 is in CV Mode END if
Programming Power Supply Registers
Present Status
Fnend
Enable Intr
Service Request and Serial Poll
OFF Intr
Print Overvoltage on Output #1
Error Detection
Stored Operating States
Introduction
Command Summary
Calibration Commands
Servlce Commands
METER?
Table C-2 Command Summary
Idata ch , Ilo , Ihi
Nidat ch . Ilo . Ihi OCP ch
TEST?
ROM? SROM? SRQ SRQ?
Table C-2 Command Summary
Page
Error Codes and Messages
Power-On Self Test Messages Error Responses
Test Responses
Hardware ERR HDW ERR CH No Model NUM
CAL Error
Skip SLF TST
CAL Locked
Page
Make Changes
Manual Backdating
United States Latin America
Agilent Sales and Support Office
Manual Updates