Manuals
/
Agilent Technologies
/
Computer Equipment
/
Power Supply
Agilent Technologies
6626A, 6628A, 6625A, 6629A manual
Models:
6629A
6625A
6626A
6628A
1
44
123
123
Download
123 pages
32.12 Kb
41
42
43
44
45
46
47
48
<
>
Specifications
Supplemental Characteristics
Install
Error codes
Dimension
Connecting The Load
If not 6626A 2A use setup
Sending a Remote Command
Alignment Procedures
Error Detection
Page 44
Image 44
Page 43
Page 45
Page 44
Image 44
Page 43
Page 45
Contents
Agilent Part No
Microfiche Part No September
Certification
Safety Summary
Safety Summary
Environmental Conditions
Declaration of Conformity
USA
What this Manual Contains
Table Of Contents
Remote Operation
Local Operation
Alignment Procedures
Command Summary
Error Messages
Programming With a Series 200/300 Computer
Page
Safety Considerations
General Information
Introduction
Instrument and Manual Identification
Accessories
Description
Model
Output Combinations Available
General Information
Basic Operation
GP-IB Board
Specifications
Output Boards
Qualifying Conditions
Definitions
Load Effect Regulation
Specifications
Output Power Watt Output
Specifications Source Effect
Load Transient Recovery Time all outputs
Supplemental Characteristics
Temperature Coefficient-Programming
Supplemental Characteristics Output Power Watt Output
Temperature Coefficient-Measurement
AC Input Power
Programming Resolution
Supplemental Characteristics High Line Inrush Current Opt
Command Processing Time see Figure
Safety Agency Compliance
Dimensions all models
Supplemental Characteristics Weight
Load Cross Regulation
Page
Output Noise Typical CC Mode
Page
Page
Location and Cooling
Installation
Initial Inspection
Input Power Requirements
Line Fuse
Nominal Voltage
Line Voltage Range
Only
Line Fuses
Fuse Agilent Part Number for ¼ X 1¼ in. fuses
Power Cord
Line Voltage Conversion
GP-IB Interface Connector
Page
Front Panel Controls and Indicators
Getting Started
45.153 14.235m
GP-IB
Controls and Indicators Controls/Indicators Description
Output Control Keys These twelve keys are output dependent
Line switch
Turning On Your Supply
Normal Self Test Indications
Checking Out Your Supply Using Local Control
Typical Display at Power-On Self-Test Errors
Current Test
Voltage Test
Overvoltage Test
Changing Resolution Range
Introduction To Remote Operation
OCP
Range V/I
Enter/Output Statements
Output
Reading the GP-IB Address
Addr
Sending a Remote Command
Often Used Commands
Getting Data From The Supply
Disp a
Getting Started
Returning the Supply to Local Mode
Page
Output Connections and Operating Information
Output Ranges
Operating Quadrants
Output Connections and Operating Information
Protection Features
Connecting The Load
Wire Size Selection
Feet
Cross Section
Meters
Multiple Loads
Remote Voltage Sensing
Positive and Negative Voltages
Remote Voltage Sensing
Remote Sense Connections
Programming Response Time with an Output Capacitor
External Trigger Circuit
Overvoltage Trigger Connections
Open Sense Leads
Power Supply Protection Considerations
Battery Charging
Parallel Operation
11. Parallel Connections with Local Sensing CV Operation
Output Type
CC Operation
Remote Sensing
Series Operation
13. Series Connections with Local Sensing CV Operation
CC Operation
Bi-Polar Operation
Page
Interface Functions
Remote Operation
GP-IB Operation
GP-IB Address Selection
Syntax Remote Operation
Power-On Service Request PON
Programming Syntax
Output Channel
Numeric Data
Output Channel Data Range
Syntax
Page
Page
Power Supply Queries Query
Header Note
Response
Initial Value
Power Supply Commands
Initial Conditions
Initial Conditions
Parameter Inital Value
Avg. Res 6625A / 6628A 6626A / 6629A
Output Outputs
Current Programming
Range Programming
Ovrst
Output On/Off
Overvoltage OV Protection
STO
Overcurrent Protection OCP
Multiple Output Storage & Recall
Clear Command
Status Reporting
UNR +CC
UNR =
RQS ERR RDY FAU
Unmask 2,XXX
Bit assignment of the Serial Poll Register
Service Request Generation
SRQ?
State RQS Bit Reprogramming Delay
Conditions for Generating a Service Request
Commands Sent
Output 705 Dspoutput 2 OK
Display On/Off
DSP Output 2 OK’’
Other Queries
ERR?
Front Panel
Explanation Response Code
Error Messages GP-IB Explanation Code
Front Panel Response
Test Responses
Code Explanation
Local Mode
Local Operation
Local Control Of Output Functions
General
Setting Voltage and Voltage Range
Front Panel Model 6626A shown
Setting Current and Current Range
Enabling/Disabling an Output
Local Control Of System Functions
RCL Enter
Displaying Error Messages
STO Enter
Page
Calibration Program
Alignment Procedures
Test Equipment and Setup Required
Alignment Procedures
Figure A-1
Figure A-3
Alignment Program
Printer is
Subend
Print
Else
END if
Repeat
Pause
Wait
2270 Print The current shunt is used 2280
If not 6626A 2A use setup
Wait for source to stabilize
Stop
END if Subend
Voltage and Current Programming
Programming With a Series 200/300 Computer
Path Names
Voltage and Current Programming with Variables
Voltage and Current Readback
Programming Power Supply Registers
Print Output 1 is in CV Mode END if
Present Status
Fnend
Service Request and Serial Poll
Enable Intr
OFF Intr
Print Overvoltage on Output #1
Error Detection
Stored Operating States
Command Summary
Introduction
METER?
Calibration Commands
Servlce Commands
Table C-2 Command Summary
Idata ch , Ilo , Ihi
Nidat ch . Ilo . Ihi OCP ch
ROM? SROM? SRQ SRQ?
TEST?
Table C-2 Command Summary
Page
Test Responses
Error Codes and Messages
Power-On Self Test Messages Error Responses
CAL Error
Hardware ERR HDW ERR CH No Model NUM
CAL Locked
Skip SLF TST
Page
Manual Backdating
Make Changes
Agilent Sales and Support Office
United States Latin America
Manual Updates