‹&RS\ULJKW$JLOHQW7HFKQRORJLHV,QF $OO5LJKWV5HVHUYHG
3DUW1XPEHU $SULO
 Flexible system features
Convenient bench-top features
 Front Panel at a Glance
Page
 T e
Front-Panel Voltage and Current Limit Settings
 OVP
Display Annunciators
 Key to
Rear Panel at a Glance
 This Book
Page
 Contents
 Contents
 Remote Interface Reference
 Error Messages
 General Information
 Safety and EMC Requirements
Safety Considerations
 Accessories
Options and Accessories
General Information Options and Accessories
Options
 General Information Description
Description
 R n i n g
 General Information Description R n i n g
 Cooling and Location
Installation
Initial Inspection
 General Information Installation Rack Mounting
Page
 Power-Line Cord
Input Power Requirements
Power-Line Voltage Selection
General Information Input Power Requirements
 Panel
Power-line module
 General Information Input Power Requirements
 Initial Operation
 Initial Operation
 Verify that the correct power-line fuse is installed
Verify the power-line voltage setting on the rear panel
Connect the power-line cord and turn on your power supply
Preliminary Checkout
 Addr 05 or RS-232
Initial Operation Power-On Checkout
Enable the outputs
 Initial Operation Output Checkout
Output Checkout
Voltage Output Checkout
 Current Output Checkout
Turn on the power supply
Adjust the voltage limit value to 1.0 volt
 T e
 Initial Operation Output Checkout
 Front-Panel Operation
 Front-Panel Operation
 Front-Panel Operation Front-Panel Operation Overview
Front-Panel Operation Overview
 Adjust the knob for the desired current limit
Set the display to the limit mode
Constant Voltage Operation
Front-Panel Operation Constant Voltage Operation
 CURRent currentMINMAX
Return to the meter mode
VOLTage voltageMINMAX
OUTPut on
 Front-Panel Operation Constant Current Operation
Adjust the knob for the desired voltage limit
Constant Current Operation
 Verify that the power supply is in the constant current mode
 Turn on the storage mode
Set up the power supply for the desired operating state
Storing and Recalling Operating States
Store the operating state in memory location
 RCL
SAV
 Level 32.0
Setting the OVP Level and Enable the OVP Circuit
Programming Overvoltage Protection
 Move to the clear mode Ovp on
Readjust the OVP trip level or the output voltage level
Checking OVP Operation
Clearing the Overvoltage Condition
 Voltprot voltageMINMAX
Clear the overvoltage condition and exit this menu
Voltprotstat Offon
Voltprotcle
 Enable the OCP circuit
Setting the OCP Level and Enable the OCP Circuit
Programming Overcurrent Protection
Front-Panel Operation Programming Overcurrent Protection
 Move to the clear mode Ocp on
Readjust the OCP trip level or the output current level
Checking OCP Operation
Clearing the Overcurrent Condition
 Currprot currentMINMAX
Clear the overcurrent condition and exit this menu
Currprotstat Offon
Currprotcle
 CV Regulation
Remote Voltage Sensing
Output Rating
Output Noise
 Remote Voltage Sensing Connections
Stability
 Outp Offon
Disabling the Output
Front-Panel Operation Disabling the Output
 Knob Locking
Disabling the Output Using an External Relay
 Self-Test
System-Related Operations
Front-Panel Operation System-Related Operations
TST?
 ERR
Error Conditions
SYSTERR?
113, Undefined header
 Disp Offon
Display Control
Disptextcle
Disptext ‘HELLO’
 Scpi Language Version
Firmware Revision Query
IDN? Returns HEWLETT-PACKARD,E3632A,0,X.X-X.X-X.X
SYSTVERS?
 Remote Interface Selection
Remote Interface Configuration
Front-Panel Operation Remote Interface Configuration
 Parity Selection RS-232
Gpib Address
Baud Rate Selection RS-232
 Gpib
To Set the Gpib Address
 RS-232
To Set the Baud Rate and Parity RS-232
Baud
Choose the RS-232 interface
 For one second
 T e Front-Panel Operation Gpib Interface Configuration
Gpib Interface Configuration
 RS-232 Configuration Overview
RS-232 Interface Configuration
Front-Panel Operation RS-232 Interface Configuration
RS-232 Data Frame Format
 Connection to a Computer or Terminal
 DTR / DSR Handshake Protocol
 RS-232 Troubleshooting
 Front-Panel Operation Calibration Overview
Calibration Overview
Calibration Security
 Calsecstat OFF, HP003632
Code
 Calsecstat ON, HP003632
 ZZ001443
Calseccode
Calsecstat
ON, ZZ00143
 Calstr ‘CAL 05-1-97’
Calibration Count
Calibration Message
 Remote Interface Reference
 Scpi
 Remote Interface Reference Scpi Command Summary
Scpi Command Summary
 VOLTageDC?
 System-Related Commands
 Status Reporting Commands
 IEEE-488.2 Common Commands
 Using the Low-Level Commands
Using the APPLy Command
Simplified Programming Overview
‘‘VOLT
 Selecting a Trigger Source
Reading a Query Response
‘‘SYSTERR?’’
‘‘TRIGSOUR IMM’’
 3RZHU6XSSO\3URJUDPPLQJ5DQJHV
 Remote Interface Reference Using the APPLy Command
Using the APPLy Command
APPLy voltage DEF MIN MAX,current DEF MIN MAX
APPLy?
 Curr Down
Output Setting and Operation Commands
Curr UP
 CURRentSTEP? DEFault
CURRentSTEP numeric valueDEFault
CURRentTRIGgered current MINimum MAXimum
CURRentTRIGgered? MINimum MAXimum
 CURRentPROTectionSTATe 01OFFON
CURRentPROTection? MINimumMAXimum
CURRentPROTectionSTATe?
CURRentPROTectionTRIPped?
 Volt Down
Volt UP
 VOLTageTRIGgered voltage MINimum MAXimum
VOLTageSTEP? DEFault
VOLTageTRIGgered? MINimum MAXimum
VOLTagePROTection voltageMINimumMAXimum
 VOLTagePROTectionSTATe?
VOLTagePROTectionSTATe 01OFFON
VOLTagePROTectionTRIPped?
VOLTagePROTectionCLEar
 MEASureVOLTage?
 Remote Interface Reference Triggering Commands
Triggering Commands
Trigger Source Choices
Bus Software Triggering
 Trigsour BUS*TRG*WAI*TRG*WAI
Trigger 705 group execute trigger
Immediate Triggering
Trigsour IMM
 TRG
Triggering Commands
 System-Related Commands
 SYSTemBEEPer
SYSTemERRor?
OUTPutRELay?
 HEWLETT-PACKARD,E3632A,0,X.X-X.X-X.X RST
IDN?
Curr Currstep
Currtrig Currprot Currprotstat Disp Outp
 RCL 1 2
SAV 1 2
 Calibration Commands
 CALibrationSECureSTATe OFF ON,code
CALibrationSECureCODE new code
CALibrationSECureSTATe?
CALibrationSTRing quoted string
 CALibrationVOLTagePROTection
 RS-232 Interface Commands
 What is an Enable Register?
What is an Event Register?
Scpi Status Registers
Remote Interface Reference Scpi Status Registers
 101
Scpi Status System
 Questionable Status Register
Questionable Status Enable register is cleared when
Questionable Status Event register is cleared when
102
 103
Standard Event Register
 104
Standard Event Enable register is cleared when
Status Byte Register
 Diihfwlqvwuxphqwwkurxjksxw
‡ RXHHFXWHWKH*CLSFOHDUVWDWXVFRPPDQG
‡ RXHHFXWHWKH*SRE 0FRPPDQG
 To Interrupt Your Bus Controller Using SRQ
Using *STB? to Read the Status Byte
Using the Message Available Bit MAV
 107
To Determine When a Command Sequence is Completed
Using *OPC to Signal When Data is in the Output Buffer
 Remote Interface Reference Status Reporting Commands
Status Reporting Commands
STATusQUEStionableCONDition?
STATusQUEStionable?
 ESE?
CLS
ESR?
OPC
 SRE?
PSC?
STB?
WAI
 111
An Introduction to the Scpi Language
 ‘‘SOURceCURRentTRIGgered’’ ‘‘APPLy 3.5,1.5’’ 112
Command Format Used in This Manual
CURRent currentMINimumMAXimumUPDOWN
 Using the MIN and MAX Parameters
Command Separators
Sourvolt Mincurr MAX
Sourvolt MIN Sourcurr MAX
 Scpi Command Terminators
Querying Parameter Settings
IEEE-488.2 Common Commands
‘‘CURR? MAX’’
 Curr currentMINMAXUPDOWN
Scpi Parameter Types
Trigsour Busimm
115
 ‡ 7KHSRZHUVXSSO\ªVLQSXWDQGRXWSXWEXIIHUVDUHFOHDUHG
Halting an Output in Progress
 RQILUPHG&RPPDQGV
Scpi Conformance Information
 SOURce VOLTageLEVelIMMediateAMPLitude voltageMINMAXUPDOWN
118
 HYLFH6SHFLILF&RPPDQGV
 IEEE-488 Conformance Information
 Error Messages
 113, Undefined header 122
Error
 Appl
Execution Errors
 Undefined header
Program mnemonic too long
Example Triggdel
Invalid character in number
 Expression errors
Block data errors
Invalid character data
Character data too long
 CALibrationSTRing command
Settings conflict
Too many errors
Data out of range
 Isolator Uart overrun error
Isolator Uart framing error
RS-232 framing error
RS-232 overrun error
 Self-Test Errors
 Calibration Errors
 Cal OVP or OCP status enabled
Bad DAC DNL error correction data
Cal checksum failed, DAC DNL error correction data
Bad OVP cal data
 Application Programs
 132
 Application Programs C++ Example for Gpibieee
++ Example for Gpibieee
Diode.c
133
 End of Program 134
Application Programs ++ Example for Gpibieee
 135
Excel 5.0 Example for Windows 3.1 and Gpib
 136
 Visuccess
137
 End of Program 138
 Tutorial
 140
 141
Overview of Agilent E3632A Operation
Tutorial Overview of Agilent E3632A Operation
 142
 143
Output Characteristics
Tutorial Output Characteristics
 144
Output Characteristics
 145
Unwanted Signals
Unregulated State
 146
 Tutorial Connecting the Load
Connecting the Load
Output Isolation
Multiple Loads
 148
Tutorial Connecting the Load R n i n g
Remote Voltage Sensing
 Capacitive Loading
Load Consideration
Inductive loading
Pulse Loading
 150
Tutorial Connecting the Load Reverse Current Loading
 Series Connections
Extending the Voltage and Current Range
Parallel Connections
Tutorial Extending the Voltage and Current Range
 152
Remote Programming
Tutorial Remote Programming
 Speed of Response Programming Down
153
 154
Reliability
Tutorial Reliability
 Specifications
 156
 157
Performance Specifications
Specifications Performance Specifications
 OCP
158
 159
Supplemental Characteristics
Specifications Supplemental Characteristics
 160
 161
Dimensions of Agilent E3632A Power Supply
 Specifications Supplemental Characteristics 162
 163
Index
 164
 165
 166
 Warranty
 According to ISO/IEC Guide 22 and EN
Declaration of Conformity