Service

Appendix C

 

 

 

 

Command Errors (these errors set Standard Event Status register bit #5)

 

100

Command error

 

 

Generic syntax error.

 

101

Invalid character

 

 

An invalid character was found in the command string.

 

102

Syntax error

 

 

Invalid syntax was found in the command string. Check for blank spaces.

 

103

Invalid separator

 

 

An invalid separator was found in the command string. Check for proper use of , ;

:

104

Data type error

 

 

A different data type than the one allowed was found in the command string.

 

105

GET not allowed

 

 

A group execute trigger is not allowed in a command string.

 

108

Parameter not allowed

 

 

More parameters were received than were expected.

 

109

Missing parameter

 

 

Fewer parameters were received than were expected.

 

110

Command header error

 

 

An error was detected in the header.

 

111

Header separator error

 

 

A character that was not a valid header separator was found in the command string.

112

Program mnemonic too long

 

 

The header contains more than 12 characters.

 

113

Undefined header

 

 

A command was received that was not valid for this instrument.

 

114

Header suffix out of range

 

 

The value of the numeric suffix is not valid.

 

120

Numeric data error

 

 

Generic numeric data error.

 

121

Invalid character in number

 

 

An invalid character for the data type was found in the command string.

 

123

Exponent too large

 

 

The magnitude of the exponent was larger than 32000.

 

124

Too many digits

 

 

The mantissa of a numeric parameter contained more than 255 digits, excluding leading zeros.

128

Numeric data not allowed

 

 

A numeric parameter was received but a character string was expected.

 

130

Suffix error

 

 

Generic suffix error

 

131

Invalid suffix

 

 

A suffix was incorrectly specified for a numeric parameter.

 

134

Suffix too long

 

 

The suffix contains more than 12 characters.

 

138

Suffix not allowed

 

 

A suffix is not supported for this command.

 

140

Character data error

 

 

Generic character data error

 

Series N5700 User’s Guide

119

Page 119
Image 119
Agilent Technologies N5700 manual Command error, Invalid character, Syntax error, Invalid separator, Data type error

N5700 specifications

Agilent Technologies, now part of Keysight Technologies, is renowned for its innovative solutions in electronic measurement and instrumentation. Among its impressive portfolio, the Agilent N5700 series of power supplies stands out, providing precision, reliability, and versatility for a range of applications in test and measurement.

The N5700 series features multiple models, each designed to meet the varying power requirements of test systems and electronic devices. One of its key characteristics is its adjustable output voltage and current, allowing users to set parameters according to specific test needs. With outputs ranging from 0 to 60 V and up to 6 A, the N5700 series caters to both low and high-power applications effectively.

A notable technology integrated into the N5700 series is its advanced measurement capabilities. The built-in voltmeter and ammeter enable real-time monitoring of output voltage and current, ensuring precise control over the power supplied to the device under test. This feature is particularly advantageous in troubleshooting and optimization scenarios, providing engineers with immediate feedback on performance.

The N5700 also embraces the latest in power supply control technology with its intuitive user interface. The front panel incorporates a clear display and simple navigation controls, allowing users to program settings easily and access functions without extensive training. Additionally, remote programming capabilities via GPIB, USB, or LAN facilitate integration into automated test setups, enhancing productivity and efficiency.

Thermal management is another hallmark of the N5700 series. Its design ensures effective heat dissipation, enabling reliable operation even under demanding conditions. This robustness is critical in environments where consistent performance is essential, such as in research laboratories and manufacturing facilities.

Furthermore, safety features are thoughtfully included in the N5700 series, such as overvoltage protection, overcurrent protection, and short-circuit protection. These elements assure users that their devices and test setups remain secure during testing, minimizing the risk of damage.

In summary, the Agilent N5700 series power supplies encapsulate the fusion of precision, advanced measurement technology, user-friendly design, thermal management, and robust safety features. This combination makes them an invaluable tool for engineers and researchers engaged in electronic testing and development across various industries. With its versatility and reliability, the N5700 series continues to play a pivotal role in advancing electronic measurement methodologies.