AT-MC601 and AT-MC602 Installation and User’s Guide

Configuring the Subscriber Unit

In rare instances, you may need to use the configuration software on the Subscriber unit to attempt link recovery. If the configuration software detects a problem with the Subscriber unit while you are connected to the Provider unit, it will prompt you to use the software on the Subscriber unit by displaying a pop-up error message. On these occasions, follow the procedure described in ”Starting a Configuration Session” on page 36 and then continue with the instructions in this section.

After you have selected the correct port and clicked the OK button, the

AT-MC60x Configurator Select Mode screen will appear, as displayed in

Figure 25.

Figure 25 Select Mode

There are two options on the Select Mode screen: Normal and Install.

These options are described below:

Normal

The Normal mode sets the units to operate under normal parameters. The units will attempt to establish a link using the parameters you set on the Configuration screen while connected to the Provider unit. See ”Configuration” on page 38 for a description of the Configuration screen. Using the Normal mode will only allow the units to establish links that meet the criteria you have set. The disadvantage to using the Normal mode is that if either of the upstream or downstream speeds you have set are unattainable, the link attempt will fail because the units are not set to use the default parameters as back-ups.

Install

The Install mode enables a watchdog timer to monitor the link attempt process. If the network extenders are not able to establish a link using the parameters you set on the Provider unit within a reasonable amount

45

Page 45
Image 45
Allied Telesis AT-MC602 manual Configuring the Subscriber Unit, Normal, Install