AT-MC601 and AT-MC602 Installation and User’s Guide
39
Actual (Mbps)
Displays the actual data transfer rate on the line. The software
automatically detects this speed.
Min (Mbps)
Allows you to adapt the data transfer rate by setting a minimum
speed.
Max (Mbps)
Allows you to adapt the data transfer rate by setting a maximum
speed.
The maximum and minimum speeds in Mbps available in the pull-down
menus are:
0.94
1.06
1.41
1.88
2.11
2.81
3.75
4.22
5.63
7.50
8.44
11.26
15.01
16.88 (upstream only)
Status
This field will display “Select speed to set” until you have selected data
rates from the upstream and downstream pull-down menus and set the
rates by clicking the Apply button. Then reports on the status of the
attempt to configure the speeds selected from the upstream and
downstream pull-down menus will appear in this field. A successful
configuration attempt will cycle though the following status reports:
Looking for link status...
Checking signal/noise ratio
Loading a Configuration DS=1.41 US=2.81
(This report will keep repeating with progressively higher
upstream and downstream values until the set rate or the
highest possible rate has been achieved.)
Saving config on EEPROM - S Side
Saving config on EEPROM - P Side
Done