Alto-Shaam 1020ESG, 1218ESG manual 2020ESG, 76-5/8” x 49-13/16” x 45-3/16” 1946mm x 1264mm x 1148mm

Models: 610ESG 2020ESG 714ESG 1020ESG 1010ESG 1218ESG

1 33
Download 33 pages 35.63 Kb
Page 14
Image 14
20•20ESG

5-7/8" (148mm)

[D] 4-9/16" (116mm) [A,B] 4-3/8" (110mm)

[C] 3-9/16" (89mm) 76-5/8” x 49-13/16” x 45-3/16” (1946mm x 1264mm x 1148mm)

19-15/16"

(506mm)

Water Drain (Side Back)

2020ESG

49-13/16" (1264mm)

 

 

 

 

 

 

 

 

 

 

 

45-3/16" (1148mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42-9/16" (1080mm)

 

 

 

 

47-13/16" (1214mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26-9/16" (675mm) 19-11/16" (500mm) 17-1/4" (438mm)

A = UNTREATED WATER B = TREATED WATER C = ELECTRICAL

D = GAS

 

C

A

Steam

Vents

B

(Top)

D

 

[D] 4-5/8" (116mm)

2" (50mm)

55-7/16"

(1407mm)

73-13/16" (1875mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-15/16" (226mm)

65-5/8" (1667mm)

74-9/16" (1893mm)

76-5/8" (1946mm)

7-11/16" (195mm)

44" (1118mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2"

 

 

 

2-3/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(49mm)

 

(56mm)

 

Water Drain

(Bottom)

30-5/8"

(1374 x 1245 x 2159mm) (778mm) Manual backgroundManual background

32-13/16"

(833mm)

 

 

 

 

 

 

DIMENSIONS: H x W x D

 

 

 

 

 

 

 

 

 

 

EXTERIOR:

 

 

 

 

 

 

 

 

 

 

 

76-5/8” x 49-13/16” x 45-3/16” (1946mm x 1264mm x 1148mm)

 

 

 

 

 

 

EXTERIOR WITH RECESSED DOOR:

 

 

 

 

 

 

 

76-5/8” x 53-13/16” x 45-3/16” (1946mm x 1366mm x 1148mm)

 

 

 

 

 

 

INTERIOR:

 

 

 

 

 

 

 

 

 

 

 

54-15/16” x 25-1/4” x 33-7/8” (1395mm x 640mm x 860mm)

WATER REQUIREMENTS

 

 

 

WATER QUALITY MINIMUM STANDARDS

 

 

 

TWO (2) COLD WATER INLETS - DRINKING QUALITY

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM

ONE (1) TREATED WATER INLET:

3/4” NPT*

* Can manifold off of

WATER QUALITY STANDARDS WILL VOID THIS WARRANTY.

 

ONE (1) UNTREATED WATER INLET: 3/4” NPT*

one 3/4” line.

It is the responsibility of the purchaser to ensure that incoming water supply is

LINE PRESSURE:

 

30 to 90 psi

2.8 to 6.2 bar

compliant with the specifications listed through adequate treatment measures.

WATER DRAIN: 1-1/2” CONNECTION WITH A 2” MINIMUM

Installation of the CombiGuardTM Water Filtration System is recommended, but

AIR GAP INSTALLED AS CLOSE TO THE OVEN AS POSSIBLE

this system may not address all water quality issues present.

 

 

 

 

 

 

 

CLEARANCE REQUIREMENTS

 

 

 

Contaminant Inlet Water Requirements (untreated water)

LEFT

6” (152mm) RECOMMENDED SERVICE ACCESS: 18” (457mm)

Free Chlorine Less than 0.1 ppm (mg/L)

 

 

Hardness Less than 3 gpg (52 ppm)

 

 

20” (508mm) FROM HEAT PRODUCING EQUIPMENT

 

 

 

 

Chloride Less than 30 ppm (mg/L)

 

RIGHT

4” (102mm) TOP: 20” (508mm) FOR AIR MOVEMENT

 

 

 

pH 7.0 to 8.5

 

BACK

4” (102mm) BOTTOM: 5-1/8” (130mm) FOR LEGS

 

Alkalinity Less than 50 ppm (mg/L)

 

 

 

 

 

 

 

 

Silica Less than 12 ppm (mg/L)

 

 

 

 

 

 

 

Total Dissolved Solids (tds) Less than 60 ppm

 

 

 

 

 

 

GAS REQUIREMENTS (TYPE MUST BE SPECIFIED ON ORDER)

INSTALLATION REQUIREMENTS

 

 

 

CONNECTED ENERGY LOAD: 190,000 Btu / hr (Natural Gas)

Oven must be installed level.

 

 

 

 

 

 

 

 

170,000 Btu / hr (Propane)

Hood installation is required.

 

 

 

 

 

 

HOOK-UP: 3/4” NPT

 

Water supply shut-off valve and back-flow preventer.

 

 

 

 

Alternate burner orifice is required for installation sites at

 

MINIMUM CONNECTED PRESSURE: 5.5” W.C. (Natural Gas)

 

elevations of 2,000 feet (610m) above sea level.

 

 

 

 

 

9” W.C. (Propane)

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM CONNECTED PRESSURE: 14” W.C.

 

 

 

 

 

 

 

ELECTRICAL (DEDICATED CIRCUIT REQUIRED)

 

 

2020ESG

 

2020ESG / sk

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

PHASE

CYCLE/HZ

 

 

AWG

 

AMPS

kW

 

AMPS

kW

 

 

 

 

 

 

 

 

 

 

110 – 120

1

50/60

 

NEMA L5-30P, 30A, 125V Plug, AWG 12

15.8

1.81

 

SK NOT AVAILABLE

208 – 240

1

50/60

 

Bare End, 3 Wire plus ground, AWG 12

8.6

1.80

 

10.4

2.49

208 – 240

3

50/60

 

Bare End, 4 Wire plus ground, AWG 12

8.6

1.80

 

10.4

2.49

WEIGHT

 

 

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET

900 lb est

(408 kg)

 

 

FULL-SIZE PANS:

20” x 12” x 2-1/2”

 

 

Forty (40)

 

SHIP

1227 lb

(557 kg)

 

 

GN 1/1:

530 x 325 x 65mm

 

 

Forty (40)

 

CRATE DIMENSIONS: (L x W x H)

 

 

GN 2/1:

650 x 530 x 65mm

 

 

Twenty (20)

 

 

54” x 49” x 85”

 

FULL-SIZE SHEET PANS:*

18” x 26” x 1”

 

 

Twenty (20)

 

(1374 x 1245 x 2159mm)

 

ON WIRE SHELVES ONLY

 

 

 

 

 

 

 

 

 

 

 

 

480 lb (218 kg) MAXIMUM

 

 

 

 

 

 

 

 

 

VOLUME MAXIMUM: 300 quarts (380 liters)

 

 

 

 

 

*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY

 

 

 

 

COMBITOUCHTM ESG SERIES • GAS INSTALLATION MANUAL • 12.

Page 14
Image 14
Alto-Shaam 1020ESG, 1218ESG, 1010ESG 2020ESG, 76-5/8” x 49-13/16” x 45-3/16” 1946mm x 1264mm x 1148mm, 1374 x 1245 x 2159mm