INSTALLATION
ELECTRICAL
MODEL | VOLTAGE | PHASE | CIRCUIT | AWG |
6•10esG AND | 1 | 20 A | 2 WIRE | |
6•10esG/SK |
|
|
|
|
7•14esG AND | 1 | 20 A | 2 WIRE | |
7•14esG/SK |
|
|
|
|
10•10esG AND | 1 | 20 A | 2 WIRE | |
10•10esG/SK |
|
|
|
|
10•20esG AND | 1 | 20 A | 2 WIRE | |
10•20esG/SK |
|
|
|
|
12•18esG AND | 1 | 20 A | 2 WIRE | |
12•18esG/SK |
|
|
|
|
20•20esG AND | 1 | 30 A | 2 WIRE | |
20•20esG/SK | 1 |
| 3 WIRE | |
| 3 |
| 4 WIRE |
OTHER VOLTAGES AVAILABLE:
Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz
An electrical wiring diagram is located behind the control panel on the left side of the oven. This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram.
Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific oven model. For supply connections, locate the wire size posted on the label located on the electrical control box cover, behind the service panel.
Before operating the oven, check all cable connections in the electrical connection area for tightness since connections can loosen during transport.
NOTE: After both water and electrical connections have been completed, operate the oven in any cooking mode for a period of 15 minutes and recheck the main power connections at the terminal block to make certain they remain tight.
380-415V:
To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an
An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following
symbol .
NOTE: Refer to local codes for connecting appliance to an electrical circuit that is protected by an external GFCI outlet.
DANGER
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
DANGER
AVERTISSEMENT: Directives pour la prise de courant électrique Cet appareil est muni d'une fiche à trios branches (prise de Courant) afin de vous proéger des chocs et doit être branché Directemet dans un receptacle adequate de prise do courant À trios branches. II ne faut pas couper ou enlever une banche De cette fiche.
D A N G E R
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
COMBITOUCHTM ESG SERIES • GAS INSTALLATION MANUAL • 13.