Alto-Shaam 2020ESG Installation, CombiTouch ERROR CODES, See Motor Control Error Code list. page

Models: 610ESG 2020ESG 714ESG 1020ESG 1010ESG 1218ESG

1 33
Download 33 pages 35.63 Kb
Page 28
Image 28
Manual background

INSTALLATION

CombiTouch ERROR CODES

Error

Error call out in Display

Description of Error

Possible reason

Code

 

 

 

 

 

 

 

E34

Steam Generator Drain

Water level in steam

— Scale build up inside the steam generator drain

 

Pump Fault

generator does not drop

pump.

 

 

during cleaning program

— Scale build up inside the steam generator affecting

 

 

 

water level probes.

 

 

 

— Generator drain pump is faulty

 

 

 

— Connection issue at drain pump.

 

 

 

— No output to pump from relay board.

 

 

 

 

E36

Steam Temperature High

Oven cavity temperature is

— Water supply is shut off.

 

 

too high when operating in

— Low water pressure.

 

 

a steam mode or cleaning

— Wiring or connection issue.

 

 

program

— Water injection pipe obstructed.

 

 

 

— Water fl ow control valve plugged or defective.

 

 

 

— Dual solenoid valve Y-1 obstructed or defective.

 

 

 

— No output to solenoid valve form relay board.

 

 

 

 

E51

No Water In Boiler

Water inside steam generator

— Water supply is shut off.

 

 

does not reach low water

— Low water pressure.

 

 

level

— Generator drain cap missing or loose.

 

 

 

— Generator drain pump is not sealing.

 

 

 

— Generator drain pump elbow leaking.

 

 

 

— Faulty or scaled water level probe.

 

 

 

— Faulty or plugged dual solenoid valve assembly.

 

 

 

— Wiring or connection issue.

 

 

 

— No output to dual solenoid from relay board.

 

 

 

 

E53

Fan Motor High

Fan motor too hot

— Exhaust hood is not operating properly.

 

Temperature

 

— Check LED fl ashes on the Motor Control.

 

 

 

See Motor Control Error Code list. (page 28).

 

 

 

— Connection Issue on Hall Effect sensor.

 

 

 

— Fan wheel is not operating.

 

 

 

— Hall sensor does not detect motor rotation.

 

 

 

 

E54

Fan Motor 2 High

20.20 lower fan motor too hot

— Exhaust hood is not operating properly.

 

Temperature

 

— Check LED fl ashes on the Motor Control.

 

 

 

See Motor Control Error Code list. (page 28).

 

 

 

— Connection Issue on Hall Effect sensor.

 

 

 

— Fan wheel is not operating.

 

 

 

— Hall sensor does not detect motor rotation.

 

 

 

 

E55

Vent not open

Browning valve does not

— Alignment issue between motor cam and vent

 

 

open

motor safety switch (micro switch).

 

 

 

— Fault vent valve (motor).

 

 

 

— Fault vent valve safety switch (micro switch).

 

 

 

— Wiring or connection problem.

 

 

 

 

 

 

 

continued on next page

COMBITOUCHTM ESG SERIES • GAS INSTALLATION MANUAL • 26.

Page 28
Image 28
Alto-Shaam 2020ESG, 1218ESG, 1010ESG, 1020ESG Installation, CombiTouch ERROR CODES, See Motor Control Error Code list. page