10•20ESG
|
|
|
| ||
[D] |
|
|
|
| (1148mm) |
|
|
|
| ||
[A,B] |
|
| |||
[C] | (506mm) |
|
| (1077mm) | |
Water Drain |
|
| |||
(89mm) |
|
|
| ||
(Side Back) |
| ||||
|
|
| (325mm) |
| (575mm) |
| C | Steam Vent | (1875mm)13/16" |
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
| A | (Top) |
|
|
|
|
|
|
|
|
|
| B |
|
|
|
|
|
|
|
|
|
|
| D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Drain |
| |
|
|
|
|
|
|
|
|
| (Bottom) |
| |
|
|
| [D] | - |
|
|
|
|
|
| |
|
|
|
|
| 73 |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
| 2" (50mm) |
|
|
|
| (778mm) |
| ||
| A = UNTREATED WATER |
| (805mm) |
|
|
|
| ||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||
| B = TREATED WATER |
|
|
| 44" (1118mm) | 2" | (833mm) |
| |||
| C = ELECTRICAL |
|
|
|
| (50mm) | (56mm) |
|
| ||
|
|
|
|
|
|
|
|
| |||
| D = GAS |
|
| DIMENSIONS: H x W x D |
|
|
|
| |||
|
|
| (1407mm) |
|
|
|
|
| |||
|
|
|
|
|
| EXTERIOR: |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| EXTERIOR WITH RECESSED DOOR: |
| ||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| INTERIOR: |
|
|
|
|
|
|
|
|
|
|
| ||||||
WATER REQUIREMENTS |
|
|
| WATER QUALITY MINIMUM STANDARDS |
| ||||||
TWO (2) COLD WATER INLETS - DRINKING QUALITY | USING A WATER SUPPLY NOT MEETING | ||||||||||
ONE (1) TREATED WATER INLET: | 3/4” NPT* | * Can manifold off of | WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. |
| |||||||
ONE (1) UNTREATED WATER INLET: 3/4” NPT* | one 3/4” line. | It is the responsibility of the purchaser to ensure that incoming water supply is | |||||||||
LINE PRESSURE: |
| 30 to 90 psi | 2.8 to 6.2 bar |
| compliant with the specifications listed through adequate treatment measures. | ||||||
WATER DRAIN: | Installation of the CombiGuardTM Water Filtration System is recommended, but | ||||||||||
AIR GAP INSTALLED AS CLOSE TO THE OVEN AS POSSIBLE | this system may not address all water quality issues present. |
| |||||||||
|
|
|
|
|
| ||||||
CLEARANCE REQUIREMENTS |
|
|
| Contaminant Inlet Water Requirements (untreated water) | |||||||
LEFT | 6” (152mm) RECOMMENDED SERVICE ACCESS: 18” (457mm) |
| Free Chlorine Less than 0.1 ppm (mg/L) |
| |||||||
|
| Hardness Less than 3 gpg (52 ppm) |
| ||||||||
| 20” (508mm) FROM HEAT PRODUCING EQUIPMENT |
|
|
| |||||||
|
|
| Chloride Less than 30 ppm (mg/L) |
| |||||||
RIGHT | 4” (102mm) TOP: 20” (508mm) FOR AIR MOVEMENT |
|
| ||||||||
|
| pH 7.0 to 8.5 |
| ||||||||
BACK | 4” (102mm) BOTTOM: |
| Alkalinity Less than 50 ppm (mg/L) |
| |||||||
|
|
|
|
|
|
| Silica Less than 12 ppm (mg/L) |
| |||
|
|
|
|
|
| Total Dissolved Solids (tds) Less than 60 ppm |
| ||||
GAS REQUIREMENTS (TYPE MUST BE SPECIFIED ON ORDER) |
| INSTALLATION REQUIREMENTS |
|
| |||||||
CONNECTED ENERGY LOAD: | 105,000 Btu / hr |
| Oven must be installed level. |
|
|
| |||||
|
|
| Hood installation is required. |
|
|
| |||||
MINIMUM CONNECTED PRESSURE: 5.5” W.C. (Natural Gas) |
|
|
| ||||||||
Water supply |
| ||||||||||
|
|
| 9” W.C. (Propane) |
|
| ||||||
|
|
|
| Alternate burner orifice is required for installation sites at |
| ||||||
MAXIMUM CONNECTED PRESSURE: 14” W.C. |
|
| |||||||||
| elevations of 2,000 feet (610m) above sea level. |
| |||||||||
|
|
|
|
|
|
| |||||
ELECTRICAL (DEDICATED CIRCUIT REQUIRED) |
|
|
| 10●20ESG | 10●20ESG / sk | ||||||
VOLTAGE | PHASE | CYCLE/HZ |
|
| AWG |
| AMPS | kW | AMPS | kW | |
110 – 120 | 1 | 50/60 |
| NEMA | 9.2 |
| 1.05 | 13.7 | 1.57 | ||
| OTHER VOLTAGES AVAILABLE: Range 200 – 415V – 1 or 3 ph, 50 or 60 Hz |
|
|
|
|
| |||||
WEIGHT |
|
| CAPACITY |
|
|
|
|
|
|
| |
NET | 573 lb est | (260 kg) |
| 20” x 12” x |
|
|
| Twenty (20) |
| ||
SHIP | 875 lb | (397 kg) |
|
| GN 1/1: | 530 x 325 x 65mm |
|
|
| Twenty (20) |
|
CRATE DIMENSIONS: (L x W x H) |
|
| GN 2/1: | 650 x 530 x 65mm |
|
|
| Ten (10) |
| ||
| 45” x 53” x 59” | 18” x 26” x 1” |
|
|
| Ten (10) |
| ||||
(1143 x 1346 x 1499mm) | ON WIRE SHELVES ONLY |
|
|
|
|
|
| ||||
|
|
|
|
|
| 240 lb (109 kg) MAXIMUM |
|
|
| ||
|
|
|
|
| VOLUME MAXIMUM: 150 quarts (190 liters) |
| |||||
|
|
| *ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY |
|
|
|
|
COMBITOUCHTM ESG SERIES • GAS INSTALLATION MANUAL • 10.