| 12•18ESG | |||
|
|
|
|
|
|
|
|
|
| ||
|
| [D] |
|
|
| (1148mm) |
| ||||
|
| (506mm) |
| (1077mm) |
| ||||||
|
| [C] |
|
| |||||||
|
|
|
| [A,B] |
|
|
| ||||
|
|
|
| (89mm) | Water Drain |
|
| ||||
|
|
|
| (Side Back) |
|
| |||||
|
|
|
|
| (325mm) | (575mm) |
| ||||
|
|
| C | Steam Vent | (1875mm)13/16" |
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
| A |
| (Top) |
|
|
|
|
|
|
|
|
| B |
|
|
|
|
|
|
|
|
|
|
| D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Drain |
| |
|
|
|
|
|
|
|
|
| (Bottom) |
| |
|
|
|
| [D] | - |
|
|
|
|
| |
|
|
|
|
|
| 73 |
|
|
|
|
|
|
|
|
| 2" (50mm) |
|
|
| ||||
|
| A = UNTREATED WATER |
| (805mm) |
| (650mm) |
| ||||
|
|
|
|
|
| ||||||
|
| B = TREATED WATER |
|
|
|
|
| ||||
|
|
|
|
|
| (840mm) | (185mm) |
|
|
| |
|
| C = ELECTRICAL |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
| D = GAS |
|
|
|
|
|
|
|
| |
|
|
|
|
| (1407mm) |
| DIMENSIONS: H x W x D |
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| EXTERIOR: |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| EXTERIOR WITH RECESSED DOOR: |
| |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| INTERIOR: |
|
|
|
|
|
|
|
|
|
|
| |||||
WATER REQUIREMENTS |
|
|
|
| WATER QUALITY MINIMUM STANDARDS |
| |||||
TWO (2) COLD WATER INLETS - DRINKING QUALITY | USING A WATER SUPPLY NOT MEETING | ||||||||||
ONE (1) TREATED WATER INLET: | 3/4” NPT* * Can manifold off of | WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. |
| ||||||||
ONE (1) UNTREATED WATER INLET: 3/4” NPT* | one 3/4” line. | It is the responsibility of the purchaser to ensure that incoming water supply is | |||||||||
LINE PRESSURE: |
| 30 to 90 psi | 2.8 to 6.2 bar | compliant with the specifications listed through adequate treatment measures. | |||||||
WATER DRAIN: | Installation of the CombiGuardTM Water Filtration System is recommended, but | ||||||||||
AIR GAP INSTALLED AS CLOSE TO THE OVEN AS POSSIBLE | this system may not address all water quality issues present. |
| |||||||||
|
|
|
|
| |||||||
CLEARANCE REQUIREMENTS |
|
|
|
| Contaminant Inlet Water Requirements (untreated water) | ||||||
LEFT | 6” (152mm) RECOMMENDED SERVICE ACCESS: 18” (457mm) | Free Chlorine Less than 0.1 ppm (mg/L) |
| ||||||||
| Hardness Less than 3 gpg (52 ppm) |
| |||||||||
| 20” (508mm) FROM HEAT PRODUCING EQUIPMENT |
|
|
| |||||||
|
|
| Chloride Less than 30 ppm (mg/L) |
| |||||||
RIGHT | 4” (102mm) TOP: 20” (508mm) FOR AIR MOVEMENT |
|
| ||||||||
|
| pH 7.0 to 8.5 |
| ||||||||
BACK | 4” (102mm) BOTTOM: |
| Alkalinity Less than 50 ppm (mg/L) |
| |||||||
| Silica Less than 12 ppm (mg/L) |
| |||||||||
Total Dissolved Solids (tds) Less than 60 ppm |
| ||||||||||
CLEARANCE FROM COUNTER SURFACE |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |||
GAS REQUIREMENTS (TYPE MUST BE SPECIFIED ON ORDER) |
| INSTALLATION REQUIREMENTS |
|
| |||||||
CONNECTED ENERGY LOAD: | 105,000 Btu / hr |
| Oven must be installed level. |
|
| ||||||
|
|
| Hood installation is required. |
|
| ||||||
MINIMUM CONNECTED PRESSURE: 5.5” W.C. (Natural Gas) |
|
| |||||||||
Water supply |
| ||||||||||
|
|
| 9” | W.C. (Propane) |
|
| |||||
|
|
|
| Alternate burner orifice is required for installation sites at |
| ||||||
MAXIMUM CONNECTED PRESSURE: 14” W.C. |
|
| |||||||||
| elevations of 2,000 feet (610m) above sea level. |
| |||||||||
|
|
|
|
|
|
|
| ||||
ELECTRICAL (DEDICATED CIRCUIT REQUIRED) |
|
|
|
| 12●18ESG | 12●18ESG / sk | |||||
VOLTAGE | PHASE | CYCLE/HZ |
|
|
| AWG |
| AMPS | kW | AMPS | kW |
110 – 120 | 1 | 50/60 |
|
| NEMA | 9.2 | 1.05 | 13.7 | 1.57 | ||
| OTHER VOLTAGES AVAILABLE: Range 200 – 415V – 1 or 3 ph, 50 or 60 Hz |
|
|
|
| ||||||
WEIGHT |
|
| CAPACITY |
|
|
|
|
|
| ||
NET | 660 lb est | (299 kg) |
|
| 20” x 12” x |
| |||||
SHIP | 789 lb | (358 kg) |
|
|
| GN 1/1: | 530 x 325 x 65mm |
| |||
CRATE DIMENSIONS: (L x W x H) |
|
|
| GN 2/1: | 650 x 530 x 65mm |
| Twelve (12) |
| |||
| 45” x 53” x 52” |
| 18” x 26” x 1” |
|
| Twelve (12) |
| ||||
(1143 x 1346 x 1321mm) |
| ON WIRE SHELVES ONLY |
|
|
|
|
| ||||
|
|
|
|
|
|
| 288 lb (131 kg) MAXIMUM |
|
| ||
|
|
|
|
|
| VOLUME MAXIMUM: 180 quarts (228 liters) |
| ||||
|
|
| *ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY |
|
|
|
COMBITOUCHTM ESG SERIES • GAS INSTALLATION MANUAL • 11.