Alto-Shaam 1218ESG, 1010ESG, 1020ESG, 714ESG, 2020ESG manual Water Valve, Water Drainage, Installation

Models: 610ESG 2020ESG 714ESG 1020ESG 1010ESG 1218ESG

1 33
Download 33 pages 35.63 Kb
Page 24
Image 24
WATER VALVE

INSTALLATION

WATER VALVE

SHUT-OFF VALVE SHOWN SHUT-OFF VALVE SHOWN

IN THE OFF POSITION

NOTE:

THE SHUT-OFF VALVE

MUST BE IN THE OPEN POSITION

WHEN THE OVEN IS BEING USED.

WATER DRAINAGE

The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is supplied with a 1-1/2-inch (41mm) NPT thread.

A union is required. Install a 1-1/2-inch (41mm) diameter connection, drain line and clamp into place. The drain line must always be a positive gradient

away from the Combitherm oven and not more than 12-inches (305mm) before an air gap.

NOTE: In the U.S.A., this equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. [BOCA], and the Food Service Sanitation Manual of the Food & Drug Administration [FDA].

If several units are to be connected to one drain

 

2”2"(51mm))

pipe, the dimensions of the pipe must be sufficient

 

Air Gap

to allow an unobstructed water drain system.

 

 

11--1/2"(41mm)diameterr NPT

NPTat backat backof ovenof oven

 

 

WASTE PIPE

11--1/2"1/2”toto2"2”minimumdiameter

(c.

to

)

(c. 38mmto

51mm)

1-1/2” (41mm) diameter connection

required

Condensate Pan Clean Out

COMBITOUCHTM ESG SERIES • GAS INSTALLATION MANUAL • 22.

Page 24
Image 24
Alto-Shaam 1218ESG, 1010ESG, 1020ESG Water Valve, Water Drainage, Installation, Shut-Off Valve Shown In The Off Position