Alto-Shaam Gas Fryer s e r v i c e c o n t r o l troubleshooting, unit troubleshooting, Problem

Models: ASF-60G Gas Fryer

1 37
Download 37 pages 18.81 Kb
Page 28
Image 28
s e r v i c e

s e r v i c e

c o n t r o l troubleshooting

PROBLEM

CAUSE

SOLUTION

No power

Circuit breaker OFF

Check and reset

 

Appliance not plugged in

Plug in cord

 

Defective 24VAC transformer

Replace transformer

 

 

Replace controller

No sound

Inoperable speaker

Replace controller

Button problem

Inoperable key

Replace controller

PROBE is displayed

Defective temperature probe

Replace temperature probe

 

Probe not plugged in

Plug in probe

Reading wrong temperature

Defective temperature probe

Replace temperature probe.

Not heating

Defective element, relay, con-

Replace defective part

 

tactor or gas valve

 

 

Defective controller

Replace controller

unit troubleshooting

PROBLEM

CAUSE

SOLUTION

No power

Circuit breaker OFF

Check and reset

 

Appliance not plugged in

Plug in cord

 

Drain switch turned to the

Turn drain switch to the “closed” position

 

“open” position

 

 

Master switch turned to the

Turn master switch to the “on” position

 

“off” position

 

Fryer will not heat

Gas valve is in the “off”

Turn gas valve to the “on” position

 

position

 

 

Gas hose is not connected

Connect gas hose

 

Hi-limit is tripped

Press the hi-limit reset button located behind

 

 

the front access door

 

No oil in frypot

Add oil to frypot

Baskets will not drop

Fuse is blown on basket lift

Replace fuse

 

relay board

 

 

Interference with basket lift

Check basket lift mechanism and remove

 

mechanism

interference

MN-35207 • Gas Fryer Operation & Care Manual • 26