Alto-Shaam MN-29245 Wat Er Connect Io Ns, One Suggested Method Of Installation, Ins Ta Llation

Models: MN-29245

1 38
Download 38 pages 49.94 Kb
Page 27
Image 27
WAT ER CONNECT IO NS

INS TA LLATION

WAT ER CONNECT IO NS

WATER RE QUIREMENTS

 

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE (1)

TREATED WATER INLET:

3/4" NPT*

ONE (1)

UNTREATED WATER INLET:

3/4" NPT*

LINE PRESSURE:

30 to 90 psi

* Can manifold off of one 3/4" line

2.8 to 6.2 bar

 

REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS

WATER DRAIN: 1-1/2"CONNECTION WITH AIR GAP

Flush the water line at the insta llati on s ite.

Install water intake filters ( provided) [see figure 1] before connecting the oven to the water su pply.

A hose conne ctor is supplied for flexi ble hose conn ection to the COLD water so urce.

PIPE SEAL ING TAP E (TEFLON®) MUST BE USED A T ALL CONNECT ION POINTS. The use of a pipe sealing compoun d i s n ot r eco mmend ed.

Incoming cold water connection

T connection

Cold water line to untreated oven connection

ONE SUGGESTED

METHOD OF INSTALLATION

Water Filter

Cold water

Treated cold

line to filter

water to treated

or treatment

connection on oven

system

 

Install water intake filters

Fig. 1

COMBIGUARD™

FI-23014

Alto- Shaa m now o ffers a v arie ty of water fi ltration sys tems

for Combithe rm®.

 

 

The CombiGuar d™ 10 & 20 trip le-gu ard wate r filt ration

sys tem filters d irt , sedi men t, and other d ebris as sm all as 1/2

micron. This syste

m a lso s ignifi cantly r edu ces c hlo rine

con tent to pr otec t against corrosive chl orine compo unds .

Combi Guar d imp rove s equip ment ef ficie ncy, reduce s s ervice

requireme nts an d e xtends the life of the Comb itherm.

Filtration syst em inc lud es one fil ter cartri dge.

The CombiGuar d™ BWS Bl ended Water S yste m u tilize s

reverse osm osis t o r emo ve m ore than

97% of the tot al

dissol ved solid s from wa ter whi ch can

be precise ly blend ed

with filtered and treated wa ter.

 

Refe r to pa ge 6 for

addition al orderi ng i nformation.

NOTE:

BOTH TREATED A ND UN TREATE D WATER CO NN ECTIONS MUST BE CONN ECTE D FOR PROPER OPERATION OF THE OVEN . BOTH CONN ECTIO NS CA N BE TREATED WATER , BUT SHOULD NEVER BE CONN ECT ED TO ONLY UNTR EATE D WATER.

UNIONS OR FLEXIBLE LINES SHOULD BE USED TO A LLOW FOR OVEN

MOVE MEN T W HEN BEING SERVICED OR CLEAN ING IS NEED ED.

REFER TO DIMEN SION DRAWINGS BEGINNIN G ON PAGE 7 FOR PROPER INTA KE LOCA TIONS .