Amana ARG7302 Test and Adjust Oven Burner Flame, Adjusting Air Shutter, Removing Oven Bottom

Models: ARG7302

1 60
Download 60 pages 53.71 Kb
Page 14
Image 14
Adjusting Air Shutter

Adjusting Air Shutter

1.Remove 4 burner control knobs from range.

Exposes 2 screws on burner control panel.

2.Remove 2 screws from burner control panel.

Panel drops slightly after screws are removed.

3.Grasp bottom of burner control panel, gently lift and pull out panel until clear of burner valve stems.

After burner control panel clears valve stems, continue to roll panel until free from range. Set aside. See Pivot Point in figure.

Gas valve and orifice hood are visible after burner control panel is removed.

Test and Adjust Oven Burner Flame

Properly adjusted oven burner flames are blue with a distinct deep blue inner cone approximately ½ inch long. When using natural gas, flame should not have any yellow flame when burning. Some yellow flame when burning LP\propane gas is normal.

1/2"

Properly Adjusted Flame

A

B

 

D

C

 

A—Burner Control Knob

B—Pivot Point

C—Burner Control Panel

D—Screw

Burner Control Panel

4.Slide air shutter open or closed depending on appearance of burner flame.

If flame is yellow and does not hold its shape, open air shutter.

If flame is blowing or noisy, close air shutter.

5.Reassemble burner control panel.

Close

Open

Adjusting Air Shutter

Flame should not be visible in the oven cavity when burning and should not extend into the oven cavity beyond the removable oven bottom.

Removing Oven Bottom

!CAUTION

To avoid risk of cuts, wear protective gloves when removing oven bottom. Sharp edges around oven bottom can cut.

1.Pull oven bottom forward and lift out.

2.Replace oven bottom.

Burner Area

14

Page 14
Image 14
Amana ARG7302 manual Test and Adjust Oven Burner Flame, Adjusting Air Shutter, Removing Oven Bottom