Electrical Connection Clearance

Electrical Connection Clearance

Electrical connection must be located in the area shown. Electrical connection must not interfere with gas connection.

A Gas Supply Location

D

B

C

Gas Supply Location

Gas supply must be located in the area shown. Gas connection must not interfere with the electrical connec- tion.

A

BC

A—2 inches (Both sides)

B—19½ inches

C—12 inches

D—6 inches

Electrical Connection Clearance

Gas Connection Requirements

Before connecting this appliance to the gas supply piping system, confirm installation meets the requirements of local codes, or in the absence of local codes, with the National

B

A

A—26 inches

B—20 inches

C—2¼ inches

D—4 inches

Gas Supply Location

D

Fuel Gas Code, ANSI Z223.1-Latest Edition.

When installed in mobile housing, installation is to be in accordance with CSA standard Z241.1 gas equipped mobile housing.

The installation of appliances designed for manufactured (mobile) home installation must conform with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such standard is not applicable, the Standard for Manufactured Home Installation, ANSI225.1/NFPA 501A-Latest Edition, or with local codes or the standard CAN/CSA-z240MH, “Mobile Homes”, and with local codes where applicable.

The installation of appliances is to be in accordance with CAN1-B149.1 or B149.2 installation code for gas burning appliances and equipment and/or local codes. Part 1 and/ or local codes.

Gas Supply Pressure

!CAUTION

To avoid property damage, maximum gas supply pressure must not exceed 14" WCP.

Appliance and individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.5kPa) (14" WCP).

Appliance must be isolated from gas supply piping system by closing manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa) (14" WCP).

Gas supply pressure for checking regulator setting must be at least 1" WCP above manifold pressure shown on rating label.

7