Pressure Regulator Location

Pressure Regulator Location

Remove rear cover to expose pressure regulator.

Regulator Cover

Oven Shutoff Valve

Gas valve to oven is turned on at factory, but could accidently be turned off during installation. Verify valve is turned on.

Converting for Use with Natural Gas or Propane Gas

This range arrives from factory adjusted for use with natural gas. If using LP/propane gas is desired, range must be converted. See “Type 1” or “Type 2” regulator.

!WARNING

To avoid electric shock that can cause personal injury or death, disconnect main electrical supply to range before servicing.

Converting Type 1 Pressure Regulator for Use with LP/ Propane

1.Remove pressure regulator cap with a wrench.

2.Remove plastic insert from pressure regulator cap.

Plastic insert fits tightly in cap.

3.Reverse plastic insert and carefully push plastic insert firmly into hole in pressure regulator cap.

Cap must show “LPG10” or “LP10”.

B

A

C

H

RG

A A

Off

 

H

R

G

 

A A

 

On

A—Cap

B—Plastic Insert (LP setting)

C—Spring Location

Type 1 Pressure Regulator

4.Place pressure regulator cap on pressure regulator and tighten.

• Insert should not disturb spring in body of regulator.

Check Oven Shutoof Valve