Amana XRSR687BW Before Calling Service, Ice & Water, Topic, Possible Cause, Solution, Operation

Models: XRSR687BW XRSS267BW XRSS267BB XRSS687BB

1 320
Download 320 pages 7.96 Kb
Page 23
Image 23
Before Calling Service

 

 

 

 

 

 

 

 

 

Before Calling Service

 

OPERATION

 

 

(continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOPIC

 

POSSIBLE CAUSE

 

SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerator runs too

 

Controls need to be adjusted.

 

See the controls section in your Owner’s Manual for

 

frequently (continued)

 

 

 

assistance in how to adjust your controls.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door is not closing properly

 

Refrigerator is not level. See Installation Instructions for

 

 

 

 

 

 

 

 

 

 

details on how to level your unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for internal obstructions that are keeping door

 

 

 

 

 

 

 

 

 

 

from closing properly (i.e. improperly closed drawers,

 

 

 

 

 

 

 

 

 

 

ice buckets, oversized or improperly stored containers

 

 

 

 

 

 

 

 

 

 

or foodstuffs, etc.).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check gaskets for proper seal. Clean, if necessary,

 

 

 

 

 

 

 

 

 

 

according to cleaning instructions in Owner’s Manual.

 

 

 

 

 

 

 

ICE & WATER

 

 

 

 

 

 

 

 

 

 

 

Water appears cloudy

 

Air or air bubbles in water.

 

This is normal when first using dispenser and will

 

 

 

 

 

 

 

 

 

 

disappear with use.

 

 

 

 

 

 

 

Particles in water and/or

 

Carbon dust from water filter cartridge.

 

Initial water ejected through cartridge may contain

 

ice cubes.

 

 

 

harmless carbon dust flushed from cartridge. Particles are

 

 

 

 

 

 

 

 

 

 

safe for consumption. Will disappear after the first few

 

 

 

 

 

 

 

 

 

 

uses.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Concentrations of minerals in water will

 

Particles are not harmful and naturally occur in

 

 

 

 

 

 

 

 

form particles when water becomes frozen

 

water supplies.

 

 

 

 

 

 

 

 

and melts.

 

 

 

 

 

 

 

 

 

No indicator lights are lit

 

Freezer door is not closed.

 

Verify that freezer door is closed. Power is removed from

 

on dispenser control

 

 

 

the control when freezer door is opened.

 

(some models)

 

Refrigerator is not plugged in.

 

Plug in unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse is blown, or circuit breaker needs to

 

Replace any blown fuses. Check circuit breakers for any

 

 

 

 

 

 

 

 

be reset.

 

tripped circuits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power outage has occurred.

 

Call local power company listing to report outage.

 

 

 

 

 

 

 

Neither ice nor water is

 

Freezer door is not closed.

 

Verify that freezer door is closed. Power is removed from the

 

dispensed when pads are

 

 

 

control when freezer door is opened.

 

pushed (some models)

 

Controls are in lock mode.

 

See Dispenser control instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water tank is filling.

 

At initial use, there is an approximate 45-second delay in

 

 

 

 

 

 

 

 

 

 

dispensing while the internal water tank is filling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ice maker or ice maker-equipped unit has just

 

Wait 24 hours for ice production to begin and for ice maker to

 

 

 

 

 

 

 

 

recently been installed or a large amount of ice

 

restock after emptied.

 

 

 

 

 

 

 

 

has just been used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water filter is clogged or needs to be changed.

 

Change water filter.

 

 

 

 

 

 

 

Ice maker is not producing

 

Ice maker has just recently been installed or a

 

Wait 24 hours for ice production to begin and for ice maker to

 

enough ice or ice is

 

large amount of ice has just been used.

 

restock after emptied.

 

malformed (some models)

 

Water pressure is too low.

 

Low water pressure can cause valve to leak. Water pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

must be between 20 to 100 pounds per square inch to function

 

 

 

 

 

 

 

 

 

 

properly. A minimum pressure of 35 pounds per square inch is

 

 

 

 

 

 

 

 

 

 

recommended for units with water filters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water filter is clogged or needs to be changed.

 

Change water filter.

 

 

 

 

 

 

 

Ice maker is not producing

 

Ice maker arm is not in correct position

 

Confirm ice maker arm is down. See Automatic Ice Maker

 

ice (some models)

 

 

 

section in your Owner’s Manual for details.

 

 

 

 

 

 

 

 

Household water supply is not reaching

 

Check water connection procedure in your Installation

 

 

 

 

 

 

 

 

water valve

 

Instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water supply tubing has kinks.

 

Turn off water supply and remove kinks. If kinks cannot be

 

 

 

 

 

 

 

 

 

 

removed, replace tubing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water pressure is too low.

 

Water pressure must be between 20 to 100 pounds per square

 

 

 

 

 

 

 

 

 

 

inch to function properly. A minimum pressure of 35 pounds

 

 

 

 

 

 

 

 

 

 

per square inch is recommended for units with water filters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check freezer temperature.

 

See the controls section in your Owner’s Manual for assistance

 

 

 

 

 

 

 

 

 

 

on how to adjust your controls. Freezer must be between 0 to

 

 

 

 

 

 

 

 

 

 

2°F (-18 to –17°C) to produce ice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ice bin is not installed properly

 

See ice bin section for proper installation and alignment.

 

 

 

 

 

 

 

 

 

 

 

23