Amana XRSS267BB Water Filter Data, Specifications, Performance Data, Service Flow Rate Maximum

Models: XRSR687BW XRSS267BW XRSS267BB XRSS687BB

1 320
Download 320 pages 7.96 Kb
Page 25
Image 25
Water Filter Data

Water Filter Data

System Specification and Performance Data Sheet

Refrigerator Water Filter Cartridge Model OWF-51

Specifications

Service Flow Rate (Maximum)

0.75 GPM (2.83 L/min)
Rated Service Life OWF-51-NI300 (Maximum)

300

gallons/ 1135 liters

Rated Service Life OWF-51-WI500 (Maximum)

500

gallons/ 1892 liters

Maximum Operating Temperature

100° F/38° C
Minimum Pressure Requirement
35 psi/ 138 kPa

Minimum Operating Temperature

33° F/ 1° C
Maximum Operating Pressure
120 psi/ 827 kPa

General Use Conditions: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs.

DO NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

The retractable water filtration system uses a OWF-51 replacement cartridge (see your distributor to order). Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system. Please refer to the applicable section in this Owner's Manual for general operation, maintenance requirements and troubleshooting.

This systems has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.

Performance Data*

 

 

 

Average

 

 

 

 

Influent challenge

Effluent

%

M axim um

Min. Required

Inlet

Substance

concentration

Average

Reduction

Effluent

Reduction

pH

Lead

0.15 mg/L +/-10%

0.001 m g/L

99.33%

0.001 m g/L

0.010 m g/L

6.5

Lead

0.15 mg/L +/-10%

0.002 m g/L

98.66%

0.003 m g/L

0.010 m g/L

8.5

Cyst

Minimum 50,000/L

1count/m L

99.99%

3 count/m L

> 99.95%

NA

Turbidity

11 +/-1 NTU

0.12 NTU

98.98%

0.18 NTU

0.5 NTU

NA

Lindane

0.002 mg/L +/-10%

0.00005 m g/L

97.62%

0.00005 m g/L

0.00002 m g/L

NA

Atrazine

0.009 mg/L +/-10%

0.0002 m g/L

97.93%

0.0006 m g/L

0.003 m g/L

NA

Chlorine

2.0 mg/L +/-10%

0.09 m g/L

95.26%

0.17 m g/L

>

NA

75%

 

at least 10,000

 

 

 

>

 

Particulate**

particles/m L

900 count/mL

99.68%

2400 count/mL

NA

85%

2,4-D

0.210 mg/L +/-10%

45.45 ug/L

84.42%

100 ug/L

0.0017 m g/L

NA

 

107 to 108 fibers/L;

 

 

 

 

 

 

fibers greater than

 

 

 

 

 

 

10 micom eters

 

 

 

 

 

Asbestos

in length

0.16 M FL/m L

99.96%

0.16 MFL/m L

99%

NA

*Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under standard laboratory conditions, however, actual performance may vary. Health Claim Performance tested and certified by NSF International

**Particle size range classification of test. Particles used were 0.5 –1 microns.

Pentapure, Incorporated

1000 Apollo Road

Eagan, Minnesota U.S.A.

Tested and Certified by NSF International against ANSI/NSF Standards

42 & 53 in models OWF50-W1500 and OWF50-N1300 for the reduction of:

Standard No. 42: Authetic Effects

Standard No. 53: Health Effects

Taste & Odor Reduction

Chemical Reduction Unit

EPA EST #35917-MN-1

®

Chlorine Reduction Class 1

Lead, Atrazine, Lindane & 2,4-D Reduction

Mechanical Filtration Unit

Mechanical Filtration Unit

Particlate Reduction Class 1

Cyst, Turbidity, & Asbestos Reduction

25

Page 25
Image 25
Amana XRSS267BB Water Filter Data, Specifications, System Specification and Performance Data Sheet, GPM 2.83 L/min